学术论文百科

建筑给水排水论文3000字怎么写

发布时间:2024-07-12 08:37:10

建筑给水排水论文3000字怎么写

去高校译云找个兼职翻译帮你弄咯,都是些大学老师或者学生,收费也不高的,而且擅长翻译论文

求一篇建筑给排水英文论是批才有枕木

MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 给排水设计 饮用水和污水 Sanitary Design Water and sewage water 设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 Design bases Design Brief and Municipal integrated network drawing offered by the Condition drawings from architectural Current national design codes and related stipulations 给水系统 通过一根DN200的进水管将水引入水表安装在进水管上,离红线1米处供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池由环路管网向必需的室外消火栓和绿化带的喷淋器供水 Water supply system For water supply of this project, DN200 water intake pipes are led Water meters are installed on the intake pipes 0 m away from the red The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop 设计范围 包括红线内的饮用水,污水,雨水,建筑消防 Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red 给排水水池与消防水池分开,容量为100m3 体操馆供水管埋地敷设 Sanitary water pool is separated from fire water pool, volume of sanitary water pool is Water supply pipes for the stadium will be laid in the 用水量标准 - 体育馆: 15升/顾客·日 K=0 - 宾馆: 150升/人·日 K=0 - 餐厅: 50升/顾客·日 K=0 - 工作人员: 25升/人·日 K=0 - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水5升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K=0 - Hotel: 150L/visitor·day K=0 - Restaurant: 50L/customer·day K=0 - Staff 25L/person·day K=0 - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water Unforeseen water consumption: 20% of the daily water Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: 5L/s·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机为此饮用水系统安装循环泵机房 设在地下室的水除了机房当饮用水机不被使用时,应排空,以免水质腐败 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵 在更衣间旁设置电热水器,为淋浴和洗盥供应热水 为楼板清洁安装一定数量的水龙头 Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the When there is no use, portable water will be drained completely to avoid Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and Certain number of water taps are installed for floor- 用水量 最大日用水量:200m3/日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: 200m3/day Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统总冷却水用量为460m3/在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h)进水温度37Co,出水温度32Co 补充水量 9,6 m3/补充水由市政供水网直接提供 Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation Total water consumption of cooling towers is 460m3/ On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/ Make-up water of the cooling towers will be supplied directly by the municipal 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用)用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心0m3 消防水箱和消防稳压装置分别安装在车库的四面墙 In the fire water pump room, there are hydrant pumps (one operation, one standby), sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby) Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, are provided in fire equipment Four 0m3 fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the 消防用水 消火栓:室内按40升/秒,室外按30升/秒,火灾延续时间按3个小时计 自动喷洒按22升/秒,火灾延续时间按1小时计 卷帘水幕用水量 5升/秒·米,火灾延续时间按3个小时计 消火栓:室内,室外用水量皆为756m3; 自动喷洒用水量为2 m3; 卷帘水幕用水量为 270m3; 一次火灾用水量为861,2; Water for fire protection Water consumption standard for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration is 3h Sprinkler: 22L/s, fire duration is 1h Drencher for rolling shutter: 5L/s·m, fire duration is 3h Water consumption for fire protection Hydrant: indoor and outdoor water consumptions are 756m3 respectively Sprinkler: 2 m3 Drencher for rolling shutter: 270m3 Water consumption for one fire: 105,2 m3 消火栓的布置 在整个建筑物内沿墙,沿柱,沿走廊,风塔上及楼梯附近设有必要数量的室内消火栓,消火栓间距小于30米消火栓管网水平,竖向皆成环状布置,消火栓箱内配有DN65消火栓一支,25米衬胶水龙带一条,φ19毫米喷咀水枪一支,并配消防卷盘(DN25消火栓一支,30米胶管,φ9毫米喷咀水枪一支)且设有可直接启动消火栓泵的按钮;在室内消火栓箱下设有磷酸铵盐手提式灭火器箱室内消火栓系统在室外设有三组水泵接合器 Hydrant arrangement Necessary number of hydrants are installed indoors along the wall, columns, corridors, and staircases, at intervals of less than Hydrant networks are connected as a loop both horizontally and Inside each hydrant box, a DN65 hydrant, a 25m long rubber lined hose, a water nozzle of φ19mm, hose reel (a DN25 hydrant, a 30m long rubber lined hose and a water nozzle ofφ9mm), and a direct starting button for the hydrant pump are Under each indoor hydrant box, a portable ammonium phosphate powder extinguisher box is There are three sets of pump adopters being installed outdoors for the indoor hydrant 消防系统 防水泵房及消防水池 供水管DN200在红线内连成环路管网,管网上安装 一定数量的消火栓两根DN200供水管分别引入供应楼内两个消防泵房内的消防水池消防水池总容量不应小于4000m3, 每个为 Fire protection system Water pump room and water pool for fire protection The lead-in pipes (DN200) are connected as a loop inside the red line, on the loop, certain number of hydrants are Two water supply pipes (DN200) are led into the fire water pools at each fire water pump room in In consideration of the importance of the project, the volume of the fire water pools should be not less than 4000m3, each is 自动喷淋系统 自动喷淋系统安装在全建筑范围,除了室外和高于10 米的房间喷淋泵安装在地下的消防泵房内报警阀设置在地下的消防泵房内和中间的消防设备中心内,水流显示器设在每个防火分区内 Sprinkler system Sprinkler systems will be provided inside the whole building except outside areas and roomshigher than 10m, with sprinkler pumps installed in the underground fire water pump Alarming valves installed in underground fire water pump rooms and four fire equipment centers in the middle, water flow indicators are installed by fire 除了安装一个封闭喷淋系统,将为地下车库设置一个泡沫喷淋系统餐厅内安装93oC启动的自动喷淋头,但在其它房间,仅安装93oC启动的普通和快速反应自动喷淋头三组泵接合器安装在室外 Besides an enclosed sprinkler system, a foam sprinkler system composed of a proportioning mixer and a foam concentrated tank is provided for the underground Sprinkler actuated at 93oC are provided in the restaurants, but in other rooms, only ordinary sprinklers and fast response sprinklers actuated at 68oC are Three sets of pump adaptors for this system will be installed 排水系统 为排水系统设置污水主立管和特别垂直排气管排气管与污水管在每层连接,污水排出体操馆餐厅的污水首先在油脂分离池中处理,然后排入室外排水网给排水污水将被在化粪池收集和处理,然后排入市政排水管网化粪池在输送区旁最大天排水量为870m3/天 Drainage system Main vertical sewage pipes and special vertical vent pipes are provided for the drainage The vent pipes are connected with sewage pipe at each floor; sewage water is drained out of Sewage water in the restaurants and garage are treated in the grease and oil separation tank, and then discharged into the outdoor drainage Sanitary sewage water is collected and treated in the septic tank, then drained into the municipal The septic tanks are located besides the Maximum daily drainage amount is 870m3/ 卷帘水幕系统 地下车库设置有卷帘水幕系统水幕泵安装在消防水泵房内,采用开式雨淋头,电动或手动控制十组泵接合器安装在室外 Drencher system for rolling shutters Rolling shutter protected by drenchers are provided for the underground garage, the drencher pumps are installed in the fire water pump rooms, open drencher heads are selected, and are controlled both by electrically and Ten pump adapters will be installed outdoors for this 地下室内污水设有污水坑,废水设有废水坑,生活污水,废水经潜污泵提升排至室外排水管网,潜污泵的启停皆由磁性浮球控制器的控制 地下汽车库废水设有废水坑,废水经潜污泵提升排至室外,经隔油池处理后排入室外雨水管网 There are cesspits for sewage water and wastewater pits for wastewater in the basement, the sewage and wastewater is sucked up and drained to the outdoor drainage networks by submerged sewage Operation of the pumps is controlled by the magnetic floating ball Wastewater pits are provided for the underground garage, wastewater is sucked up and drained to outdoor oil separation tank by submerged sewage pumps, after treated, wastewater is drained to the outdoors rainwater 在柴油发电机房,变配电房和通讯设备机房设低压二氧化碳气体灭火系统 Low pressure CO2 extinguisher systems are provided in diesel generator rooms, transformer substations and telecommunication equipment 在本建筑内按"建筑灭火器配置设计规范"在每个消火栓箱下设手提式灭火器箱,箱内设有必要数量的磷酸铵盐手提式灭火器 According to the Code for Design of Extinguisher Disposition in Buildings, portable fire extinguisher box, in which there are necessary number of portable ammonium phosphate powder extinguishers, will be installed under every hydrant 在每个消防电梯井底旁设有消防排水坑,废水经潜污泵提升排至室外 Fire water drain pit is provided at side of bottom of each fire elevator well, waste water will be sucked up and drained out by the 雨水系统 雨水排水屋顶采用压力流排水 雨水设计重现期按P=10年计算,降雨历时为5分钟,暴雨强度公式按Q=002(1+568lgP)/(t+983)465计算 沿柱在屋面设置雨水沟雨水通过雨水沟收集,然后进入雨水头和下排管,然后到室外雨水观察井 Rainwater system Pressurized drainage system is adopted for roof rainwater drainage Here, return period P=10 years, rainfall duration is 5 minutes, stormwater amount is calculated by the following formula: Q=002(1+568lgT)/(t+983)465 Rainwater gutters are provided on roof along columns, Rainwater is collected in the gutter, then to rainwater heads and downpipes, and to the outdoors rainwater inspection 管材 - 生活给水管,冷却塔补水管采用铜管,氩弧焊接 - 直饮水管采用不锈管 - 消火栓管,冷却循环管,水幕管,水泵吸水管采用焊接钢管,焊接 - 自动喷洒水管,雨淋水管采用热镀锌钢管,丝扣连接或卡压连接 -二氧化碳管采用无缝钢管焊接 - 地下车库泡沫喷淋水管采用不锈钢管,卡压连接 Pipe material Copper pipes connected by argon arc welding are adopted for the sanitary water pipes, make-up water pipes for cooling Stainless stell pipes are adopted for portable water Welded steel pipes connected by welding are selected for hydrant pipes, cooling circulating pipes, drencher pipes, pump suction Hot-galvanized steel pipes connected by threads or compression-seizing are selected for sprinkler and deluge sprinler Seamless steel pipes connected by welding are selected for CO2 Stainless steel pipes connected by pressed clamp is selected for the pipes of foam sprinklers in the underground 当雨水两超出雨水沟设计量时,雨水可沿屋檐自由排放雨水被收集,然后排入市政集水池 When the amount of rainwater is more than the design value of the gutters, water is discharged naturally along the Rainwater is collected, and then drained to the municipal catch 围绕体育馆的循环池将用于喷洒运动场和作为室外绿化带的储水池 此池将作为一个循环过滤设施,可容水约500 m 喷洒压力设备和其它必须的过滤设备安装在供应楼里 The circular senic pool surround stadium will be used for spraying sportsfield and as reservoir for outdoor The pool will be used as a circular filtering facility and will be adopted with a water volume of about 500 m The spray water pressurizing equipment as well as further necessary filtering equipment will be adopted in the supply 0 制冷 0 Cooling 冷源: 空调冷负荷(估算): 本工程建筑面积共000平方米,包括观众区,休息室,更衣室,小会议室,餐厅,办公室和其它附属房空调设计日峰值冷负荷为4MW,设计日总冷负荷为3 kW Refrigerating source Cooling load of air conditioning system Total floor area for this building is 50,000sqm, which includes spectator areas, lounges, Clothing and changing rooms small meeting rooms, restaurant, office and other auxiliary Designed dayly peak cooling load is 2,4MW, designed total dayly cooling load is 3kW 每台1200kW制冷机配一台 流量为206m3/h离心泵各配一台备用泵 一次泵采用压差旁路控制 通过埋地敷管,向游泳体操馆供应冷冻水 A centrifugal pump with a flow rate of 103m3/h is provided for each 1200kW One operation pump with a standby corresponds to one Pressure difference branch control is adopted for primary pump Via earth laid pipes from supply building to gymnasium chilled water supply will be 冷源的选择: 根据建筑的实际情况,3台制冷机将安装在供应楼内的冷冻机房设计容量为4800kW 为了实现能量的效率化使用,设计方案为,1台制冷机的出力为总设计容量的50%而另2 台每台出力为总设计容量的25% 冷冻水系统的主要设备包括3台电动制冷机,一级冷冻泵,二级冷冻泵,自动控制阀等等冷冻水的供/回水温度为-7/ 12°C Selection of refrigerating source According to the real condition of the building, 3 chillers are located in the refrigerating plant rooms in the supply building, designed capacity is 2400kW For actuing in an energy efficient way one chiller about 50% of total capacity (200 kW) and two chillers with 25% of total (600 kW each)capacity each are Main equipment of chilled water system includes 3 electrical chiller, primary cool water pump, secondary chilled water pump and automatic controlled valve, supply/return temperature of the chiller is-7/ 12°C 二次泵系统:根据使用功能,各制冷机房又分成不同的循环支路 二次泵采用变频调速控制根据负荷侧供回水管的压差,控制水泵的转速 二次泵循环支路的管道采用异程式 Secondary pump system: Each refrigerating plant room is subdivided into different circulation branch loops according to use Variable-frequency speed-regulating control is adopted for secondary The rotating speed of a water pump is controlled according to the pressure difference between water supply and return Direct return system is adopted for the pipes of circulating branch of secondary pumps 空调冷冻水系统 由于本工程占地面积大,功能复杂,有连续使用,也有间歇使用,为了达到运行灵活,节能的目的,空调冷冻水系统采用两管制二次泵系统 Chilled water system Due to the large occupied area of this project, the complicated functions and the combination of continuous utilization and intermittent utilization, in order to accomplish the purpose of flexible operation and energy saving, the chilled water system is of two-pipe secondary pump 管材: 水管采用焊接钢管及无缝钢管 本工程的风管除土建风道外,均采用镀锌铁皮咬口制作每节风管之间用法兰连接 Pipe and duct materials The water pipes adopt welded steel pipes and seamless steel Air ducts for this project are made of galvanized sheet steel by seaming except ducts by civil Air ducts are connected together by 一次泵系统: 供应楼冷冻机房 2400kW制冷机配一台离心泵, 流量为412m3/配一台备用泵 Primary pump system: Chiller room supply building A centrifugal pump with a flow rate of 412m3/h is provided for 1200kW One operation pump with a standby corresponds to one 保温材料: 空调供,回水管,冷凝水管采用酚醛管壳保温 空调送,回风管以及处理后的新风管采用外贴铝箔的离心玻璃棉板保温 - 管道穿防火墙的空隙处采用岩棉材料等非燃材料填充 Thermal materials phenolic pipes are adopted for thermal insulation of water supply and return pipes for air conditioning, as well as air-conditioning condensate Aluminum foil faced glass fiber boards are adopted for thermal insulation of air-conditioning air supply and return ducts as well as fresh air ducts after Non-flammable material will be selected to fill the interspace in the fire protection wall where the ducts go 消声与隔振: 冷水机组,水泵等设备采用减振台座,弹簧减振器或橡胶减振垫减振降噪 在空调机组,新风机组,通风机的进出口采用涂胶帆布软管连接 - 水泵进出水管上采用可曲挠橡胶接头,使设备振动与配管隔离 Noise reduction and vibration isolation Shock absorption bases, spring shock absorbers on rubber shock absorption pads are adopted for equipment, such as water chiller units, pumps, etc to reduce vibration and lower Flexible rubber-coated canvas hoses are adopted far connections of inlets and outlets of air-conditioning units, fresh air handling units and Flexible rubber couplings are adopted for the water intake and delivery pipes of the pumps to isolate equipment vibration from their 0空调和通风系统 0 Air Conditioning and Ventilation Systems 方案设计范围 Scope of schematic design 空调设计 Air Conditioning Design 在体育馆内,一些区域设置空调系统这些区域划分为: 西侧地下二层的贵宾休息室 东侧地下二层酒店门廊 地下一层的输送区,技术机房,运动员更衣间,医务服务,热身区,裁判区,健身中心,酒店大堂,会议室,厨房,特许区和贵宾大堂混合区 首层的酒店大堂,酒店区,贵宾门廊,急救 In the stadium, in some ranges air conditioning systems are These ranges subdivide themselves as follows: VIP – Lobby in West of levelel -2 Hotel lobby in the east of level –2 Delivary Circle, technical Plantrooms, Changingrooms for the athletes, Medical Service and warm up area, Judges Area, Fitness Center, Hotel Lobby, Conferenz, Kitchen and Concession, Vip lobby- Mixed Zone in level -1 Hotel lobby, Hotel area, Vip lobby, Vip Area, First aid in 0

建筑给水排水论文3000字

土木工程与建筑设备工程的关系 这个论文不是太精确 你就将就着用吧。。我也是自己东拼西凑的。 正好给你用了。建筑设备是为建筑物的使用者提供生活、生产和工作服务的各种设施和设备系统的总称,是现代建筑功能得以实现的不可缺少的重要条件。它包括建筑中的给水、排水、消防、供暖、通风、空调、供电、照明等系统。是建筑学、建筑装饰、土木工程、建筑管理等专业的一门专业技术课,是一门综合性工程学科,也是一门理论和实践密切结合的专业课程。为了满足人们在日常生活中的各种需要,建筑设备在建筑行业中的地位越来越发重要近代房屋建筑为了满足生产和生活上的需要,以及提供卫生,安全而舒适的生活和工作环境,要求在建筑物内设置完善的给水,排水,供热,通风,空气调节,燃气,供电等设备系统。设置在建筑物内的设备系统,必然要求与建筑,结构及生活需求,生茶工艺设备等相互协调,才能发挥建筑物应有的功能,并提高建筑物的使用质量,避免环境污染,高效的发挥建筑物位生产和生活服务的作用,因此,见者设备工程师房屋建筑不可缺少的组成部分。该门课程要培养学生成为建筑工程专业技术人才,掌握建筑设备工程技术的基本知识,掌握设备工程的基本设计原理与施工安装方法,正确读解施工图,培养学生对工程实际问题的分析和解决能力。因此需要配合土木工程专业知识综合施工。土木工程的结构设计,施工等方面要时刻注意建筑设备的安装,及其应用。如何合理地进行建筑设备工程设计,保证建筑物的使用质量,不仅与建筑设计,结构设计,施工方法等有密切的关系,而且对生产经济人民生活具有重要的意义。可以说建筑设备与土木工程具有相辅相成的密切关系。尤其是随着人们对建筑质量,生活方面的要求的提高,以及要求智能建筑的方面。因此紧密结合建筑设备和土木工程的设计施工越来越发重要就建筑设备本省来说,随着我过各种类型的工业企业的不断建立,城镇各类民用建筑的兴建,人民生活居住条件的逐步改善,基本建设工业化施工的迅猛发展,建筑设备工程技术水平正在不断的提高,同时,忧郁近代科学技术的发展,各门学科相互渗透和相互影响。建筑设备技术也受到交叉学科的发展的影响而日新月异。例如 土木施工的工业化施工 迅速改变着建筑安装现场手工抄作的方式。还有各种智能建筑设备的更新 对土木工程施工技术也要求更高。还要考虑到建筑结构对各种设备的影响等。建筑设备的发展跟土木工程设计施工时紧密联系在一块的。 民用建筑包含两大部分,公共聚集区和住宅。公共聚集区是指商场、市场、宾馆饭店、影剧院、体育场馆、舞厅等场所,在为人们提供舒适的购物、住宿、娱乐环境的同时也会因为要使用大量的电气设备、设施,增大了电气火灾发生的危险性;而人民生活水平的迅速提高也必然用到更多更新的家庭电器产品,与这些电器产品直接接触的绝大多数是仅有使用常识而不具备电气专业知识的普通人群,不规范的用电习惯和移动延长插座的滥用等也使家庭电气火灾的发生率在逐年提高。 一、发生火灾的一些统计资料根据确切的有关数据统计,仅2007年上半年全国城镇共发生火灾95336起,死亡898人,受伤488人,直接财产损失近5乙元,可见火灾造成的人身伤亡和经济损失是非常惨重的。国务院已制定出《生产安全事故报告和调查处理条例》等一系列的防范和救助措施,同时各级主管部门对火灾防范也给予了很大的重视,使全国火灾发生趋势稳中有降。然而值得重视的是,由于电气故障引发的火灾却在逐年递增,初步统计,约为10年前的4—5倍,占火灾发生数目的四分之一以上。在电气事故引发的火灾中,其原因电气设备占10%,线路占0%,用电设备及器具占4%(其中照明器具为6%),其它为6%;在重、特大的电气火灾中,其原因短路占52%,过负荷占6%,接触不良占6%,过热占5%,漏电占8%,雷击占5%,电气故障占10%。大部分电气火灾事故是由于对电气设备运行人为地违反操作规程引发的,譬如忘了断开电热设备电源、在电热器上烘干衣服等,这些都是不规范用电酿成火灾的典型案例;使用未经检验的、不符合制造规定的电气设备和装置是造成电气火灾的另一个危险根源,譬如,白炽灯泡(或其它发热量大的光源)和电热器等由于温度过高而引燃了周围可燃物;还有很大一部分原因是由于导线过载、过电流保护装置特性差或短接导线保护开关、熔断器等引起了电源短路和接地故障。都是应该引起重视的电气火灾隐患。综上所述,电气火灾发生的起因和防范有以下几点值得注意:1、公众聚集区最严重的电气火灾隐患是电气设备、线路的温度过高,一方面在工程设计中因为没有把好关将导线选择的过小或偏小导致线路温度升高,另一方面电气线路的虚接、打火或是变压器地线?接点、配电室母排和桥架、保险丝等处都存在因施工不善,人为造成的局部温度升高都是火灾隐患,,在消防监督检查或电气设备检测过程中。可供助红外热像仪等检测设备寻找过热部位及热源,也可利用超声波探测仪查找电气线路、设备的虚接及打火现象等,还可采用红外点温仪等设备测量具体部位的温度。施工安装不规范,导致电气设备故障。电线、电缆接头外露现象最为普遍,常见的有照明灯、移动插座、配电室柜式空调、广告射灯等电源线接头外露。吊顶、电缆井、装饰墙面、商品柜台、橱柜内暗装的插座电源线接头外露也普遍存在;电气设备与可燃物间未采取有效隔离措施。加大了电气火灾的危险性,例如,有些电气设备直接安装在可燃构件上,或者电气设备采用可燃性物体作为箱体等,在日常生活中,最常见的是空气开关、漏电断路器、荧光灯镇流器、灯具控制开关、电源插座直接安装在木板上等;4、电气线路敷设保护措施不到位:(1)吊顶部位电气线路敷设存在的问题最为严重。例如,有的木质吊顶内灯具配线未穿保护管;吊顶内线缆明敷或者灯具配线进入吊顶后未采取保护措施;吊顶内灯具配线穿管保护不到位的现象也时有发生,有的导线即便穿管了但仍存有裸露部分或者配电支线的保护管没有引入接线盒或器具内;(2)电线、电缆在穿墙、金属构件、可燃构件时未采取保护措施,,有的电线、电缆未穿金属保护管敷设在可燃装饰夹层内。或者在穿木隔墙、楼梯间隔墙时,以及在线缆出入配电箱穿钢管管口处均未做应有的保护措施等:(3)室内电气线路敷设位置不当。电气线路敷设位置与热源距离过近,如:有的照明灯(特别是发热量较高的灯具)电源线贴暖气管敷设。或者电源护套线靠近散热器、金属管道敷设、缠绕在金属管上等;5、移动延长插座存在的问题尤为突出,无论是公共聚集区还是家庭中,移动延长插座的问题都比较多,很多劣质插座未使用合格的绝缘护套,移动延长插座串接使用、供电导线过,需要采取防水措施的地方(如餐厅花坛处、商场出售洗衣机、鱼缸等处)未使用防水型的移动延长插座等;6、端子导线压接不规范。空气开关和漏电断路器的接线端子及中性线汇流端子排等处的接线端子压接多根导线或多股导线无端子压接,还有接线端子压接不牢的现象时有发生;7、管理措施不到位。仓库灯具垂直下方堆放可燃物;有的发电机与明火锅炉及其它可燃物同置一室;配电柜周围堆放杂物;照明灯具与周围可燃物距离过近;电缆沟遗留有可燃性杂物等;8、很多消防用电设备、设施由于施工等原因自身就存在不同程度的火灾隐患。设计计算选型的失误使消防用电设备或导线过热或烧毁的现象时有发生在消防检查中还经常发现消防配电箱接线端子温度过热或电气设备已被烧毁不起作用等,还有空气开关外壳烧毁、导线接头外绝缘老化、断路器压接导线被锈蚀导致接触不良等,这样的消防设施、消防电路不仅在火灾时起不到应有作用。反而成为火灾发生的起因,应引起重视;9、竖井、7一同未采取防火封堵措施、高层民用建筑电缆井在每层楼板处未进行防火封堵,变压器裸母排等电气设备穿过防火隔墙孔洞时未实施防火封堵等会使火焰通过竖井或其它通路延燃,造成更大的损失。通过上面的例子可一发现 在土木工程施工中不注意消防设备的安装以及安装的位置不到位都可能给以后建筑投入使用时发生火灾带来极大的危害。建筑设备能否正确的安装在建筑物上同土木工程施工有着极大的联系。同时由于施工中出现的建筑设备的材料要求不符合结构的设计要求同样会造成建筑物使用时的一些严重的问题。我国建筑工程施工过程中,工程设备的安装作为施工安全的重要控制点,一直以来都是施工企业关注的焦点之一。工程设备的安装不仅仅影响到工程施工整体进度,其也是影响工程质量的一个重要控制点。因此加强建筑工程设备安装过程的管理,保障工程设备安装质量,已经成为建筑施工企业管理中的一项重点。文中就建筑工程设备安装过程的管理进行了简要的论述。 近年来,我国经济的飞速发展也使得我国建筑行业得到了更大的发展空间。建筑工程施工中,工程设备的安装作为影响整个工程质量的重要环节,其安装质量对于工程有着重要的影响。由于国家加大了对建筑工程设备安装的管理与监督,我国目前的建筑工程设备安装市场已经得到了较好的发展。 一、建筑工程设备安装现状分析 房屋建筑工程中的设备安装项目种类较多,电梯、中央空调、给排水设备、消防设备、高低压配电设备等。目前我国的建筑工程设备安装采用招投标形式进行,但是许多承包单位在将整体工程投标后,分包给多个小公司进行,本身只通过现场派驻几名技术人员跟踪。而派驻的技术人员也并非全天在现场。加上小公司企业技术力量薄弱,人员配备不齐全,常常造成工程设备安装施工过程留下了设备隐患。因此,加强工程设备安装监理,从源头抓起,通过材料审核、安装过程监理等多方面的监督与管理,提高工程设备安装质量。 二、建筑工程设备安装过程的管理 由于建筑工程设备安装涉及多种类的设备的安装,因此在此我们根据施工过程的不同方面,而不是针对一种设备的安装管理进行论述。 (一)建筑工程设备安装施工中材料的管理 施工材料进现场必须通过双人复核来检查进料质量,并通过材料现场检查、与设计图纸标注材料是否一致。例如:在进行供排水设备安装施工中的材料管理,首先在管材进场时要检查管材管径是否与标注管径一直,其次根据图纸对管材材质的要求检查管材材质是否符合标准要求。最后核对进场物料数量。通过这样一系列的检查,来保障供排水设备安装的质量。另外对于工程设备安装过程中使用的辅料,也必须加强监管。例如:中央空调工程安装过程中使用的密封胶,必须采用合格厂家出场的产品,避免假货的进入。材料管理员要时刻注意,进场物料的保质期、厂家等。通过主要材料与辅助用材料双重监管,保障工程施工使用材料符合要求,为建筑工程设备安装质量提供基础的保障。 (二)建筑工程设备安装施工中的质量管理 首先,施工阶段的技术质量管理。设备安装专业的施工组织设计、施工方案、各项技术质量交底目前通过检查仍然是工程质量的薄弱环节,主要问题是与“单位工程施工组织设计”脱节,与实际现场施工项目脱节,起不到真正指导施工作用。内容空洞,仍然大量抄自国家标准、设计说明和地方工艺标准,没有针对本工程具体情况,但仍然顺利通过各级审批和监理的认可。有相当工程是同一专业系统只是不同部位分包,分包单位各编各的施工方案,互不交底,相互矛盾,同一个工程没有统一质量控制管理。有的施工方案甚至不能称为“方案”,就是“原则指示”,没有具体的质量、技术成品保护措施,没有施工进度计划,缺少认真审查,也无法执行贯彻。这种现象年年讲,但改进不大,原因主要是“质保体系”不健全,有的施工项目甚至没有真正的专业管理人员,监理人员很多又是从设计院退休或其他非施工单位转业的人员,缺少实际施工管理经验,所以不能真正起到把关、控制质量管理的作用。其次,多数施工企业操作人员很少有经过专业培训上岗的工人,真正的暖卫及通风空调技工很少,高级技工几乎没有。一方面是施工中使用的大多数是农民工,所以操作质量难以有大的提高。另一方面是多数施工企业缺少企业工艺标准,均使用北京市编制的地方工艺标准,该工艺标准已编制多年,有相当部分内容已不适用。尤其目前推广应用的一些新技术、新材料方面,老的工艺标准没有这些内容。 土木工程设计施工同建筑设备安装之间的关系式紧密相连得,设计的合理 及施工的精确性对设备的影响很大,同样 设备的材料,型号是否符合结构设计施工的要求也对建筑物的使用会有很大影响。能否满足人们对建筑物的舒适性 使用的方便 是对土木工程设计施工及建筑设备共同考验。

要:近些年来,建筑给排水的最大热点是新型管材的广泛应用。传统的镀锌钢管和普通排水铸铁管由于易锈蚀、自重大、运输施工不便等原因被取而代之。目前, 建筑给排水常用管材主要有塑料管,金属管和复合管三种。现在就常用管材的一些特性,优缺点,使用范围做一简要论述。关键词:建筑给排水 管材 塑料管 金属管 复合管塑料管塑料管是合成树脂加添加剂经熔融成型加工而成的制品。添加剂有增塑剂,稳定剂,填充剂,润滑剂,着色剂,紫外线吸收剂,改性剂等。常用塑料管有:硬聚氯乙烯管(PVC-U),高密度聚乙烯管(PE-HD), 交联聚乙烯管(PE-X),无规共聚聚丙烯管(PP-R),聚丁烯管(PB),工程塑料丙烯晴-丁二烯-苯乙烯共聚物(ABS)等。塑料管的原料组成决定了塑料管的特性。塑料管的主要优点:(1)化学稳定性好,不受环境因素和管道内介质组分的影响,耐腐蚀性好。(2).导热系数小,热传导率低,绝热保温,节能效果好。(3)水力性能好,管道内壁光滑,阻力系数小,不易积垢,管内流通面积不随时间发生变化,管道阻塞机率小。(4).相对于金属管材,密度小,材质轻,运输,安装方便,灵活,简捷,维修容易。(5).可自然弯曲或具有冷弯性能,可采用盘管供货方式,减少管接头数量。其主要缺点:(1)力学性能差,抗冲击性不佳,刚性差,平直性也差,因而管卡及吊架设置密度高。(2)阻燃性差,大多数塑料制品可燃,且燃烧时热分解,会释放出有毒气体和烟雾。(3)热膨胀系数大,伸缩补偿必须十分强调。所以,在推广塑料管的同时,还需要发展技术克服其缺点。1 塑料管性能1 物理性能:塑料管的物理性能和铝塑复合管,钢管,铜管比较见表1:表1物理性能 单位 PVC-U PE PE-X PP PB ABS 钢 铜 密度 g/cm 50 95 95 90 93 02 85 89 导热系数 w/mk 16 48 40 24 22 26 50 400 热膨胀系数 mm/m°C 07 22 15 16 13 11 012 018 弹性模量 MPa 3000 600 600 900 350 2500 210000 110000 拉伸强度 MPa 40 25 >25 28 17 40 700 150 硬度 R 120 70 100 60 230HB 使用温度 °C 0-60 -60-60 -60-95 -20-95 -20-95 -20-80塑料管的物理性能影响管道的方式,用途,补偿措施和管道保温等方面。如:(1)PVC-U、PP、ABS的力学性能相对较高, 被视为“刚性管”,明装较好。反之,PE、PE-X、PB作为“柔性管”适合暗敷。(2)塑料管的使用温度及耐热性能决定了PVC-U,PE,ABS仅能用于冷水管,而PE-X,PP, PB则可作为热水管。当建筑物有热水供应系统且冷热水采用统一管材时耐热性能成为主要指标。(3)塑料管因热膨胀系数高,在塑料管路中尤其是作为热水管,采用柔性接口,伸缩节或各种弯位等热补偿措施较多。其中以PE,PP等聚烯烃类为最。施工安装时如果对此没有足够重视,并采取相应技术措施,极易发生接口处因伸缩节而拉脱的问题。(4)由于导热系数低,塑料管的绝热保温性能优良进而可减少保温层的厚度甚至无需保温。当不同塑料管之间绝热性的比较除导热系数外,还同它们各自的管壁厚度有关。2 承压性能:承压性能所涉及的内容是在一定条件下塑料管材能够承受的内压力和恒压下的破坏时间。从而确定与之有关的设计参数以及对管材的质量进行评价和监控。一般进行两项试验:液压试验和长期高温液压试验。 各种管材的承压性能见表2表2管 材 工作压力/MPa 试样试验压力/MPa 接头密封试验/MPa 爆破压力/MPa UPVC 6 42/h De≤90,4.2PNDe>90,3.36PN PEX 0/95℃6/常温 5 6 ABS 0 8/h 4~8 PB 1.6~2.5/冷水0/热水 PP-RPP-C 0/常温6/75℃ 20℃,11h,16MPa80℃,48h,8MPa80℃,170h,2MPa HDPE 0/热水6/冷水3 卫生性能:理化卫生指标。其中PE,PE-X,PP,PB和ABS易达标。而PVC-U管材在生产时应使用无毒PVC树脂和卫生及稳定剂才能满足卫生性能的要求。2 给水塑料管的应用结构形式单一,材料品种众多且性能各异常用给水塑料管的特点列表如下:表3品种 优 点 缺 点 连接方式 PVC-U 抗腐蚀力强,易于粘合,价廉,质地坚硬 有UPVC单体和添加剂渗出,不适用于热水输送;接头粘合技术要求高,固化时间较长 粘合、螺纹 HDPE 韧性好,较好的疲劳强度,耐温度性能较好;质轻,可挠性和抗冲性能好 熔接需要电力;机械连接,连接件大 挤压夹紧、热熔合、电熔合 PEX 耐温性能好,抗蠕变性能好 只能用金属件连接;不能回收重复利用 挤压夹紧 PB 耐温性能好,良好的抗拉、压强度,耐冲击,低蠕变,高柔韧性 国内还没有PB 树脂原料,依赖进口,价高 挤压夹紧、热熔合、电熔合 PP-R 耐温性好 在同等压力和介质温度的条件下,管壁最厚 热熔合 ABS 强度大,耐冲击 耐紫外线差,粘接固化时间较长 粘合、螺纹、电熔合一般情况聚氯乙烯管由于价格低廉,在不考虑水质影响,在冷水供水系统属于首选管材,而当温度较高时,可选用聚乙烯管或交联聚乙烯管、聚丙烯管、聚丁烯管。3 排水塑料管的应用材质单一:硬聚氯乙烯结构形式多样:芯层发泡管,空壁管,螺旋管,芯层发泡螺旋管,空壁螺旋管。其存在的一些问题:(1)热膨胀系数大,需设置伸缩补偿装置来解决。(2)刚度小,平直性差,需加密管卡、支架、吊架来解决。(3)耐热性差,软化温度低,需限制排水温度,限制使用场所和控制与热源的距离来解决。(4)阻燃性差,在穿越楼板、上人屋面的屋面板、防火墙、管道井井壁处需设置阻火圈和防火套管来解决。(5)抗机械冲击性差,需强化施工技术,精心施工来解决。(6)隔声性差,塑料管的噪声大于铸铁管,管道明装且管道位置靠近卧室时,问题尤为突出。降噪的方式,提高管道材质的隔声效果,芯层发泡管空壁管是基于这一思路而开发的;降噪的另一方式是改变水流条件,螺旋管是基于这一思路而开发的。将两种方式结合起来的思路是芯层发泡螺旋管和空壁螺旋管的开发。相同条件下,不同结构形式的排水塑料管,其噪声测定结果:普通管>芯层发泡管>空壁管>螺旋管排水塑料管的应用是在取代普通排水铸铁管的工作上进行的。目前,排水塑料管已可在建筑高度为100m以下的建筑物内使用,但各地区的进展很不平衡。当建筑高度大于、等于100m的高层建筑和不适宜采用排水塑料管的场合,可采用柔性抗震排水铸铁管。[next] 金属管1 镀锌钢管镀锌钢管的被取代既不意味金属管被取代,也不意味镀锌钢管在整个建筑给水领域被取代。镀锌钢管由于价格低廉、性能优越,防火性能好,使用寿命长等优点,还将在消防给水系统,尤其是自动喷水灭火系统中应用而塑料管(承压小)则不应在消防给水系统和生活-消防,生产-消防共有系统中应用。2 铜管金属管中最具优势的是铜管,铜管应用较久,优点较多,管材和管件齐全,接口方式多样,较多的应用在热水管路中,目前存在的主要问题在于铜的折出量容易超标。3 铸铁管给水铸铁管与钢管相比有不易腐蚀、造价低、耐久性好等优点,适合于埋地敷设。缺点是质脆、重量大、长度小等。连接方式一般采用承插连接。卡箍式铸铁排水管是一种新型的建筑用排水管材,60年代开始进入国际市场,经过几十年的推广和应用,这种管材已得到国际上的普遍认可。这种管材与传统的承插式铸铁排水管道相比有许多优点,是一种更新换代产品,但由于这种管材及配件价格相对较贵,所以在国内一直未能得到普及推广。4 其它:不锈钢管也受到工程技术人员的青睐,有关方面正从减少壁厚,降低价格方面着手,以利于推广。铝合金管是铝厂向给排水行业推出的新品种。镀镍钢管是和镀锌钢管性质最近,而耐腐蚀性能远远超过镀锌钢管的新颖管材,在解决了降低镀层费用和管材断口处施工现场上镍工艺后,有望在一定范围内得到采用。涂塑钢管则是在金属管材中前景看好的一种管材,且管道布置和敷设、接口方式和施工安装均与镀锌钢管相同,是这种管材最容易被接受。由于其涂层薄、价格低,也最容易被推广。复合管:复合管包括衬铅管、衬胶管、玻璃钢管。复合管大多是由工作层(要求耐水腐蚀)、支承层、保护层(要求耐腐蚀)组成。复合管一般以金属作支撑材料,内衬以环氧树脂和水泥为主, 它的特点是重量轻、内壁光滑、阻力小、耐腐性能好;也有以高强软金属作支撑,而非金属管在内外两侧,如铝塑复合管,它的特点是管道内壁不会腐蚀结垢,保证水质;也有金属管在内侧,而非金属管在外侧,如塑覆铜管,这是利用塑料的导热性差起绝热保温和保护作用。根据金属的材料可分为:(1)钢塑复合管(2)不锈钢-塑复合管,塑覆不锈钢管(3)塑覆铜管(4)铝塑复合管,交联铝塑复合管(5)衬塑铝合金管应该说复合管材是管径≥300mm以上给排水管道最理想的管材。它兼有金属管材强度大,刚性好和非金属管材耐腐蚀的优点。但它又是目前发展较缓慢的一种管材。这是因为:(1)两种管材组合在一起比单一管材价格偏高。(2)两种材质热膨胀系数相差较大,如粘合不牢固而环境温度和介质温度变化又较剧烈,容易脱开,而导致质量下降。复合管的连接宜采用冷加工方式,热加工方式容易造成内衬塑料的伸缩、变形乃至熔化。一般有螺纹、卡套、卡箍等连接方式。由于复合管尚属新型管材,我国还未有统一的设计、施工及验收规范。设计及施工人员往往套用镀锌管的工艺来进行设计与施工,故在此不作一一赘述。

MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 给排水设计 饮用水和污水 Sanitary Design Water and sewage water 设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 Design bases Design Brief and Municipal integrated network drawing offered by the Condition drawings from architectural Current national design codes and related stipulations 给水系统 通过一根DN200的进水管将水引入水表安装在进水管上,离红线1米处供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池由环路管网向必需的室外消火栓和绿化带的喷淋器供水 Water supply system For water supply of this project, DN200 water intake pipes are led Water meters are installed on the intake pipes 0 m away from the red The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop 设计范围 包括红线内的饮用水,污水,雨水,建筑消防 Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red 给排水水池与消防水池分开,容量为100m3 体操馆供水管埋地敷设 Sanitary water pool is separated from fire water pool, volume of sanitary water pool is Water supply pipes for the stadium will be laid in the 用水量标准 - 体育馆: 15升/顾客·日 K=0 - 宾馆: 150升/人·日 K=0 - 餐厅: 50升/顾客·日 K=0 - 工作人员: 25升/人·日 K=0 - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水5升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K=0 - Hotel: 150L/visitor·day K=0 - Restaurant: 50L/customer·day K=0 - Staff 25L/person·day K=0 - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water Unforeseen water consumption: 20% of the daily water Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: 5L/s·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机为此饮用水系统安装循环泵机房 设在地下室的水除了机房当饮用水机不被使用时,应排空,以免水质腐败 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵 在更衣间旁设置电热水器,为淋浴和洗盥供应热水 为楼板清洁安装一定数量的水龙头 Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the When there is no use, portable water will be drained completely to avoid Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and Certain number of water taps are installed for floor- 用水量 最大日用水量:200m3/日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: 200m3/day Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统总冷却水用量为460m3/在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h)进水温度37Co,出水温度32Co 补充水量 9,6 m3/补充水由市政供水网直接提供 Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation Total water consumption of cooling towers is 460m3/ On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/ Make-up water of the cooling towers will be supplied directly by the municipal 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用)用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心0m3 消防水箱和消防稳压装置分别安装在车库的四面墙 In the fire water pump room, there are hydrant pumps (one operation, one standby), sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby) Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, are provided in fire equipment Four 0m3 fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the 消防用水 消火栓:室内按40升/秒,室外按30升/秒,火灾延续时间按3个小时计 自动喷洒按22升/秒,火灾延续时间按1小时计 卷帘水幕用水量 5升/秒·米,火灾延续时间按3个小时计 消火栓:室内,室外用水量皆为756m3; 自动喷洒用水量为2 m3; 卷帘水幕用水量为 270m3; 一次火灾用水量为861,2; Water for fire protection Water consumption standard for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration is 3h Sprinkler: 22L/s, fire duration is 1h Drencher for rolling shutter: 5L/s·m, fire duration is 3h Water consumption for fire protection Hydrant: indoor and outdoor water consumptions are 756m3 respectively Sprinkler: 2 m3 Drencher for rolling shutter: 270m3 Water consumption for one fire: 105,2 m3 消火栓的布置 在整个建筑物内沿墙,沿柱,沿走廊,风塔上及楼梯附近设有必要数量的室内消火栓,消火栓间距小于30米消火栓管网水平,竖向皆成环状布置,消火栓箱内配有DN65消火栓一支,25米衬胶水龙带一条,φ19毫米喷咀水枪一支,并配消防卷盘(DN25消火栓一支,30米胶管,φ9毫米喷咀水枪一支)且设有可直接启动消火栓泵的按钮;在室内消火栓箱下设有磷酸铵盐手提式灭火器箱室内消火栓系统在室外设有三组水泵接合器 Hydrant arrangement Necessary number of hydrants are installed indoors along the wall, columns, corridors, and staircases, at intervals of less than Hydrant networks are connected as a loop both horizontally and Inside each hydrant box, a DN65 hydrant, a 25m long rubber lined hose, a water nozzle of φ19mm, hose reel (a DN25 hydrant, a 30m long rubber lined hose and a water nozzle ofφ9mm), and a direct starting button for the hydrant pump are Under each indoor hydrant box, a portable ammonium phosphate powder extinguisher box is There are three sets of pump adopters being installed outdoors for the indoor hydrant 消防系统 防水泵房及消防水池 供水管DN200在红线内连成环路管网,管网上安装 一定数量的消火栓两根DN200供水管分别引入供应楼内两个消防泵房内的消防水池消防水池总容量不应小于4000m3, 每个为 Fire protection system Water pump room and water pool for fire protection The lead-in pipes (DN200) are connected as a loop inside the red line, on the loop, certain number of hydrants are Two water supply pipes (DN200) are led into the fire water pools at each fire water pump room in In consideration of the importance of the project, the volume of the fire water pools should be not less than 4000m3, each is 自动喷淋系统 自动喷淋系统安装在全建筑范围,除了室外和高于10 米的房间喷淋泵安装在地下的消防泵房内报警阀设置在地下的消防泵房内和中间的消防设备中心内,水流显示器设在每个防火分区内 Sprinkler system Sprinkler systems will be provided inside the whole building except outside areas and roomshigher than 10m, with sprinkler pumps installed in the underground fire water pump Alarming valves installed in underground fire water pump rooms and four fire equipment centers in the middle, water flow indicators are installed by fire 除了安装一个封闭喷淋系统,将为地下车库设置一个泡沫喷淋系统餐厅内安装93oC启动的自动喷淋头,但在其它房间,仅安装93oC启动的普通和快速反应自动喷淋头三组泵接合器安装在室外 Besides an enclosed sprinkler system, a foam sprinkler system composed of a proportioning mixer and a foam concentrated tank is provided for the underground Sprinkler actuated at 93oC are provided in the restaurants, but in other rooms, only ordinary sprinklers and fast response sprinklers actuated at 68oC are Three sets of pump adaptors for this system will be installed 排水系统 为排水系统设置污水主立管和特别垂直排气管排气管与污水管在每层连接,污水排出体操馆餐厅的污水首先在油脂分离池中处理,然后排入室外排水网给排水污水将被在化粪池收集和处理,然后排入市政排水管网化粪池在输送区旁最大天排水量为870m3/天 Drainage system Main vertical sewage pipes and special vertical vent pipes are provided for the drainage The vent pipes are connected with sewage pipe at each floor; sewage water is drained out of Sewage water in the restaurants and garage are treated in the grease and oil separation tank, and then discharged into the outdoor drainage Sanitary sewage water is collected and treated in the septic tank, then drained into the municipal The septic tanks are located besides the Maximum daily drainage amount is 870m3/ 卷帘水幕系统 地下车库设置有卷帘水幕系统水幕泵安装在消防水泵房内,采用开式雨淋头,电动或手动控制十组泵接合器安装在室外 Drencher system for rolling shutters Rolling shutter protected by drenchers are provided for the underground garage, the drencher pumps are installed in the fire water pump rooms, open drencher heads are selected, and are controlled both by electrically and Ten pump adapters will be installed outdoors for this 地下室内污水设有污水坑,废水设有废水坑,生活污水,废水经潜污泵提升排至室外排水管网,潜污泵的启停皆由磁性浮球控制器的控制 地下汽车库废水设有废水坑,废水经潜污泵提升排至室外,经隔油池处理后排入室外雨水管网 There are cesspits for sewage water and wastewater pits for wastewater in the basement, the sewage and wastewater is sucked up and drained to the outdoor drainage networks by submerged sewage Operation of the pumps is controlled by the magnetic floating ball Wastewater pits are provided for the underground garage, wastewater is sucked up and drained to outdoor oil separation tank by submerged sewage pumps, after treated, wastewater is drained to the outdoors rainwater 在柴油发电机房,变配电房和通讯设备机房设低压二氧化碳气体灭火系统 Low pressure CO2 extinguisher systems are provided in diesel generator rooms, transformer substations and telecommunication equipment 在本建筑内按"建筑灭火器配置设计规范"在每个消火栓箱下设手提式灭火器箱,箱内设有必要数量的磷酸铵盐手提式灭火器 According to the Code for Design of Extinguisher Disposition in Buildings, portable fire extinguisher box, in which there are necessary number of portable ammonium phosphate powder extinguishers, will be installed under every hydrant 在每个消防电梯井底旁设有消防排水坑,废水经潜污泵提升排至室外 Fire water drain pit is provided at side of bottom of each fire elevator well, waste water will be sucked up and drained out by the 雨水系统 雨水排水屋顶采用压力流排水 雨水设计重现期按P=10年计算,降雨历时为5分钟,暴雨强度公式按Q=002(1+568lgP)/(t+983)465计算 沿柱在屋面设置雨水沟雨水通过雨水沟收集,然后进入雨水头和下排管,然后到室外雨水观察井 Rainwater system Pressurized drainage system is adopted for roof rainwater drainage Here, return period P=10 years, rainfall duration is 5 minutes, stormwater amount is calculated by the following formula: Q=002(1+568lgT)/(t+983)465 Rainwater gutters are provided on roof along columns, Rainwater is collected in the gutter, then to rainwater heads and downpipes, and to the outdoors rainwater inspection 管材 - 生活给水管,冷却塔补水管采用铜管,氩弧焊接 - 直饮水管采用不锈管 - 消火栓管,冷却循环管,水幕管,水泵吸水管采用焊接钢管,焊接 - 自动喷洒水管,雨淋水管采用热镀锌钢管,丝扣连接或卡压连接 -二氧化碳管采用无缝钢管焊接 - 地下车库泡沫喷淋水管采用不锈钢管,卡压连接 Pipe material Copper pipes connected by argon arc welding are adopted for the sanitary water pipes, make-up water pipes for cooling Stainless stell pipes are adopted for portable water Welded steel pipes connected by welding are selected for hydrant pipes, cooling circulating pipes, drencher pipes, pump suction Hot-galvanized steel pipes connected by threads or compression-seizing are selected for sprinkler and deluge sprinler Seamless steel pipes connected by welding are selected for CO2 Stainless steel pipes connected by pressed clamp is selected for the pipes of foam sprinklers in the underground 当雨水两超出雨水沟设计量时,雨水可沿屋檐自由排放雨水被收集,然后排入市政集水池 When the amount of rainwater is more than the design value of the gutters, water is discharged naturally along the Rainwater is collected, and then drained to the municipal catch 围绕体育馆的循环池将用于喷洒运动场和作为室外绿化带的储水池 此池将作为一个循环过滤设施,可容水约500 m 喷洒压力设备和其它必须的过滤设备安装在供应楼里 The circular senic pool surround stadium will be used for spraying sportsfield and as reservoir for outdoor The pool will be used as a circular filtering facility and will be adopted with a water volume of about 500 m The spray water pressurizing equipment as well as further necessary filtering equipment will be adopted in the supply 0 制冷 0 Cooling 冷源: 空调冷负荷(估算): 本工程建筑面积共000平方米,包括观众区,休息室,更衣室,小会议室,餐厅,办公室和其它附属房空调设计日峰值冷负荷为4MW,设计日总冷负荷为3 kW Refrigerating source Cooling load of air conditioning system Total floor area for this building is 50,000sqm, which includes spectator areas, lounges, Clothing and changing rooms small meeting rooms, restaurant, office and other auxiliary Designed dayly peak cooling load is 2,4MW, designed total dayly cooling load is 3kW 每台1200kW制冷机配一台 流量为206m3/h离心泵各配一台备用泵 一次泵采用压差旁路控制 通过埋地敷管,向游泳体操馆供应冷冻水 A centrifugal pump with a flow rate of 103m3/h is provided for each 1200kW One operation pump with a standby corresponds to one Pressure difference branch control is adopted for primary pump Via earth laid pipes from supply building to gymnasium chilled water supply will be 冷源的选择: 根据建筑的实际情况,3台制冷机将安装在供应楼内的冷冻机房设计容量为4800kW 为了实现能量的效率化使用,设计方案为,1台制冷机的出力为总设计容量的50%而另2 台每台出力为总设计容量的25% 冷冻水系统的主要设备包括3台电动制冷机,一级冷冻泵,二级冷冻泵,自动控制阀等等冷冻水的供/回水温度为-7/ 12°C Selection of refrigerating source According to the real condition of the building, 3 chillers are located in the refrigerating plant rooms in the supply building, designed capacity is 2400kW For actuing in an energy efficient way one chiller about 50% of total capacity (200 kW) and two chillers with 25% of total (600 kW each)capacity each are Main equipment of chilled water system includes 3 electrical chiller, primary cool water pump, secondary chilled water pump and automatic controlled valve, supply/return temperature of the chiller is-7/ 12°C 二次泵系统:根据使用功能,各制冷机房又分成不同的循环支路 二次泵采用变频调速控制根据负荷侧供回水管的压差,控制水泵的转速 二次泵循环支路的管道采用异程式 Secondary pump system: Each refrigerating plant room is subdivided into different circulation branch loops according to use Variable-frequency speed-regulating control is adopted for secondary The rotating speed of a water pump is controlled according to the pressure difference between water supply and return Direct return system is adopted for the pipes of circulating branch of secondary pumps 空调冷冻水系统 由于本工程占地面积大,功能复杂,有连续使用,也有间歇使用,为了达到运行灵活,节能的目的,空调冷冻水系统采用两管制二次泵系统 Chilled water system Due to the large occupied area of this project, the complicated functions and the combination of continuous utilization and intermittent utilization, in order to accomplish the purpose of flexible operation and energy saving, the chilled water system is of two-pipe secondary pump 管材: 水管采用焊接钢管及无缝钢管 本工程的风管除土建风道外,均采用镀锌铁皮咬口制作每节风管之间用法兰连接 Pipe and duct materials The water pipes adopt welded steel pipes and seamless steel Air ducts for this project are made of galvanized sheet steel by seaming except ducts by civil Air ducts are connected together by 一次泵系统: 供应楼冷冻机房 2400kW制冷机配一台离心泵, 流量为412m3/配一台备用泵 Primary pump system: Chiller room supply building A centrifugal pump with a flow rate of 412m3/h is provided for 1200kW One operation pump with a standby corresponds to one 保温材料: 空调供,回水管,冷凝水管采用酚醛管壳保温 空调送,回风管以及处理后的新风管采用外贴铝箔的离心玻璃棉板保温 - 管道穿防火墙的空隙处采用岩棉材料等非燃材料填充 Thermal materials phenolic pipes are adopted for thermal insulation of water supply and return pipes for air conditioning, as well as air-conditioning condensate Aluminum foil faced glass fiber boards are adopted for thermal insulation of air-conditioning air supply and return ducts as well as fresh air ducts after Non-flammable material will be selected to fill the interspace in the fire protection wall where the ducts go 消声与隔振: 冷水机组,水泵等设备采用减振台座,弹簧减振器或橡胶减振垫减振降噪 在空调机组,新风机组,通风机的进出口采用涂胶帆布软管连接 - 水泵进出水管上采用可曲挠橡胶接头,使设备振动与配管隔离 Noise reduction and vibration isolation Shock absorption bases, spring shock absorbers on rubber shock absorption pads are adopted for equipment, such as water chiller units, pumps, etc to reduce vibration and lower Flexible rubber-coated canvas hoses are adopted far connections of inlets and outlets of air-conditioning units, fresh air handling units and Flexible rubber couplings are adopted for the water intake and delivery pipes of the pumps to isolate equipment vibration from their 0空调和通风系统 0 Air Conditioning and Ventilation Systems 方案设计范围 Scope of schematic design 空调设计 Air Conditioning Design 在体育馆内,一些区域设置空调系统这些区域划分为: 西侧地下二层的贵宾休息室 东侧地下二层酒店门廊 地下一层的输送区,技术机房,运动员更衣间,医务服务,热身区,裁判区,健身中心,酒店大堂,会议室,厨房,特许区和贵宾大堂混合区 首层的酒店大堂,酒店区,贵宾门廊,急救 In the stadium, in some ranges air conditioning systems are These ranges subdivide themselves as follows: VIP – Lobby in West of levelel -2 Hotel lobby in the east of level –2 Delivary Circle, technical Plantrooms, Changingrooms for the athletes, Medical Service and warm up area, Judges Area, Fitness Center, Hotel Lobby, Conferenz, Kitchen and Concession, Vip lobby- Mixed Zone in level -1 Hotel lobby, Hotel area, Vip lobby, Vip Area, First aid in 0

随着能源的减少,人们逐渐变得重视节能了。在我还上小学时就教育我们节能的观念,只为了我们人类能在地球永远的生活下去。在现实生活中,人们仍不清楚怎样节能,让节能只是一个说的到,却不能全做的到的事情,往往还因缺乏科学的节约常识和“小窍门”,造成不必要的浪费现象。现在我来就介绍家庭的节电。 电饭煲节电小窍门 现在市面上的电饭煲分为两种:一种是机械电饭煲,另外一种是电脑电饭煲。使用机械电饭煲时,电饭煲上盖一条毛巾,注意不要遮住出气孔,这样可以减少热量损失。当米汤沸腾后,将按键抬起利用电热盘的余热将米汤蒸干,再摁下按键,焖15分钟即可食用。电饭煲用完后,一定要拔下电源插头,不然电饭煲内温度下降到 70度以下时,会自动通电,这样既费电又会缩短使用寿命。尽量选择功率大的电饭煲,因为煮同量的米饭,700瓦的电饭煲比500瓦的电饭煲要省时间。电脑电饭煲一般功率较大,在800瓦左右,从而节能,但价格稍贵,一般都在500元至800元之间。 电视机节电小窍门 电视机节能可以通过如下几条途径:首先控制好对比度和亮度。一般彩色电视机最亮与最暗时的功耗能相差3O瓦至50瓦,建议室内开一盏低瓦数的日光灯,把电视对比度和亮度调到中间为最佳。其次控制音量,音量大,功耗高。第三个省电的办法是观看影碟时,最好在AV状态下。因为在AV状态下,信号是直接接入的,减少了电视高频头工作,耗电自然就减少了。第四是看完电视后,不能用遥控器关机,要关掉电视机上的电源。因为遥控关机后,电视机仍处在整机待用状态,还在用电。一般情况下,待机10小时,相当于消耗半度电。最后是给电视机加防尘罩。这样可防止电视机吸进灰尘,灰尘多了增加电耗。 空调节电小窍门 空调使用过程中温度不能调得过低。因为空调所控制的温度调得越低,所耗的电量就越多,故一般把室内温度降低6至7度就行了。 制冷时室温定高1度,制热时室温定低2度,均可省电10%以上,而人体几乎觉察不到这微小的差别。 设定开机时,设置高冷/高热,以最快达到控制目的;当温度适宜时,改中、低风、减少能耗,降低噪音。 “通风”开关不能处于常开状态,否则将增加耗电量。 少开门窗可以减少房外热量进入,利于省电。 使用空调器的房间,最好使用厚质地的窗帘,以减少凉空气散失。 室内、外机连接管不超过推荐长度,可增强制冷效果。 安装空调器要尽量选择房间的阴面,避免阳光直射机身。如不具备这种条件,应给空调器加盖遮阳罩。 定期清除室外散热片上的灰尘,保持清洁。散热片上的灰尘过多,可大幅度增加耗电量。 冰箱节电小窍门 目前市场上出现的A++级节能冰箱比普通的冰箱要省电。家庭用的节能冰箱一般消耗5?8度电/天,而普通冰箱一般耗电1?5度电/天,大约可以省一半电。另外,使用冰箱的过程中,应注意以下问题: 冷藏物品不要放得太密,留下空隙利于冷空气循环,这样食物降温的速度比较快,减少压缩机的运转次数,节约电能。 在冰箱里放进新鲜果菜时,一定要把它们摊开。如果果菜堆在一起,会造成外冷内热,就会消耗更多的电量。 对于那些块头较大的食物,可根据家庭每次食用的份量分开包装,一次只取出一次食用的量,而不必把一大块食物都从冰箱里取出来,用不完再放回去。反复冷冻既浪费电力,又容易对食物产生破坏。 解冻的方法有水冲、自然解冻等几种。在食用前几小时,可以先把食物从冷藏室(4度左右)里拿到微冻室(1度左右)里,因为冷冻食品的冷气可以帮助保持温度,减少压缩机的运转,从而达到省电目的。 冰箱的摆放也有讲究,一般应该注意以下两个问题: 在摆放冰箱时,一般应在两侧预留5?10厘米、上方10厘米、后侧10厘米的空间,可以帮助冰箱散热。 不要与音响、电视、微波炉等电器放在一起,这些电器产生的热量会增加冰箱的耗电量。 节能是很重要的,人都应该用这些小窍门,不应该因嫌麻烦就不去做这些事。这些事对谁都有极大的好处的,仅仅需要举手之劳而已。有关部门也应该加大节能力度,多多宣传。让人类都节约这并不是永远都有的能源!为造福我们的后代而努力吧!

建筑给排水论文3000字

新型排水管材应用研究一、概况 根据建设部《关于发布化学建材技术与产品的公告》精神,应用于排水的新型管材主要是塑料管材,其主要品种包括:聚氯乙烯管(PVC-U)、聚氯乙烯芯层发泡管(PVC-U)、聚氯乙烯双壁波纹管(PVC-U)、玻璃钢夹砂管(RPMP)、塑料螺旋缠绕管(HDPE 、PVC-U)、聚氯乙烯径向加筋管(PVC-U)等。HDPE管由于其特殊的结构与性能,较小的投资,在排水管领域内倍受青睐。因此对新型排水管材的研究以HDPE管为主。 研究的主要内容包括:新型排水管材的内容及分类;物理力学指标;工程应用研究;施工安装、使用与维护管理等。期间进行了资料收集、工艺应用计算及研究、学习参观考察、产品理化性能测试、施工安装、使用与维护管理等研究工作,而且经过努力,顺利地将HDPE管、PVC-U等新型排水管材进行了工程的推广应用,取得了较好的效果,为在q市推广使用新型排水管材开了个好头,赢得了良好的社会效益和环境效益。 二、项目的目的、意义及内容 项目的目的、意义 目前,国内排水管材大多数采用钢筋混凝土管,钢筋混凝土管作为排水管使用存在着许多弊端: (1)理化性能不稳定,使用寿命短; (2)综合经济指标高; (3)其生产不符合节能环保政策。 因此,淘汰混凝土管,推广使用塑料管材作为其更新换代产品更加具有重要的意义。高密度聚乙烯中空壁缠绕管(简称HDPE)作为塑料管材中的佼佼者由于其特殊的结构与性能,较小的设备投资,在排水管领域内越来越受到青睐。 目前随着全国各地城市基础建设投资力度的不断加大,新型管道生产企业的不断涌现以及生产能力的不断扩大,必然会在全国掀起“管道革命”的热潮。建设部即将出台政策法规,在全国范围内禁止使用水泥管作为排水、排污管道。因此市场对复合管材的需求将急剧增大。 q市的经济发展水平一直居于省的龙头地位。城市基础建设投资的力度呈加速态势。这为q市的城市建设水平以及新型建材的开发、推广、使用水平提出了更高的要求。因此,开发新型排水管材并尽快地进行推广使用,提高技术及经济性指标,满足可持续发展方针的需要,早日为q乃至全国的城市建设发挥其应有的作用,具有非常重要的意义。 研究内容 (1)新型排水管材的内容及分类 (2)物理力学指标 (3)工程应用研究 (4)施工安装、使用与维护管理 三、国内外发展现状 上海市早在1998年以沪建材98第0511号文规定:淘汰水泥管(混凝土管),推广使用塑料管。北京市为迎接2008年奥运会,正准备淘汰水泥排水管,并计划在“十五”期间总投资2800亿元用于市政建设,其中800亿用于市政排水管网建设及污水处理。西方发达国家早在上个世纪八十年代已开发出了替代产品-塑料管材,并极力推广使用。HDPE由于其特殊的中空壁结构,使得管材比重减轻,环刚度增强,而且设备投资也较小,因此在排水管领域内越来越受到青睐。特别是在德国、韩国和日本,大口径排水管中,HDPE缠绕管的使用率分别为60%,75%和90%。韩国政府今年又拨款一兆四千亿韩元,用于HDPE中空壁缠绕管替换水泥管的工程。因此,本课题以HDPE中空壁缠绕管作为研究重点。 四、主要内容 (1)排水管材的分类 市政工程用排水管按其管材特性可分为刚性管和柔性管(塑料管)两大类。 刚性管包括铸铁管、混凝土管、陶制管等,均为传统材料制作的管道,优点是刚性好,环刚度较高,但防腐性能差,用作排污管道需做特殊防腐处理,使用寿命一般为10~20年不等。最大的缺点是易破碎(铸铁管除外),渗漏严重,易造成二次污染。 塑料排水管按其管壁结构可分为实壁塑料管和结构塑料管两大类。实壁管有硬聚氯乙烯管、玻璃钢夹砂管和PE管,结构壁管分为单/双壁波纹管、加筋管和缠绕管三大类。 (2)物理力学指标 管材特性: (1)结构独特,强度高,抗压耐冲击 (2)内壁平滑,摩阻低,过流量大 (3)耐腐蚀,无毒无污染,环保性突出 (4)连接方便,接头密封好,无渗漏 (5)重量轻,施工快捷,降低费用 (6)埋地使用寿命达五十年以上 管材物理性:(见下表)序号 项 目 单 位 性能指标 1 密度 G/cm3 94—96 2 热膨胀系数 Cm/cm℃ 11×10-5 3 抗拉强度(230) Mpa 21—24 4 弹性模量 Mpa 552—758 5 软化温度 ℃ 126 6 脆化温度 ℃ -70 (3)工程应用研究 用途: HDPE中空壁缠绕管的主要用途可包括: (1)水利工程、自来水工程输水 (2)市政工程雨水、污水排放 (3)工业废水排放、小区排水 (4)盐业输卤、渔业输水 (5)矿井、建筑物内通风系统 (6)电线、电缆护套 我们研究的重点主要是用于市政工程的雨污水排水管。 工程推广与应用 研究伊始,我们便致力于开展HDPE中空壁缠绕管的工程推广与应用的工作,作了大量的调查研究和推广论证工作。一年多来,经过主管部门、业主、设计院和生产厂家的共同努力,我们顺利地将HDPE管、PVC-U等新型排水管材进行了工程的推广应用,在h湾改造工程、砂土路改造工程的k路、a路、t路、g路采用了HDPE管;在砂土路改造工程中的y路、h采用了PVC-U管,都取得了较好的效果,为在q市推广使用新型排水管材开了个好头,赢得了良好的社会效益和环境效益。 (4)施工安装、使用与维护管理 由于HDPE管材本身的特性,以及推广初始阶段不为大多数人所了解,HDPE排水管在施工安装、使用与维护管理的许多方面都与传统管材有较大出入,带来了许多新的问题,同时也给人们对HDPE管材的接受和使用带来了心理疑虑和障碍,主要包括: 管道之间的连接,即接口形式; 管道与检查井的连接; 沟槽开挖与基础处理; 回填与管道抗浮; 管材环刚度的确定与选用; 相关标准与技术规程的不尽完善,等等。 根据我们对HDPE管的研究以及在推广使用过程中的总结,针对以上各方面内容,特提出以下几点: 管道之间的接口形式建议使用密封胶圈柔性接口,不推荐使用热缩套连接。 由于材料的收缩率不同,HDPE管道与砖混检查井的连接处易导致渗漏,建议采用防水翼环,防水翼环可与不同管径的HDPE短管连接好后,直接用水泥砂浆浇注成砌块,在砌检查井时可根据流水底高,直接砌入,省时省力。从远期考虑,应注重塑料预制检查井的应用研究与推广。 在地下水位较高、流沙等不良地基处施工,应开挖一段、施工一段并迅速回填,注意防止管道的上浮、偏移与下窝,一旦发生,必须返工。 目前管道的规格一般仅有4KN/M2、8KN/M2两种,规格系列不够丰富,应进一步细分,以节省成本,提高管材的价格竞争力。 应尽快出台相关的国家标准与技术规程,以利推广。 五、原材料及环境保护 高密度聚乙烯中空壁缠绕管的主要原料是PE(聚乙烯),原料可以全部国产化。 本项目在生产中无废水、废气、烟尘排放,无振动,车间内噪音在80dB以下,厂房外噪音60dB以下,不对环境造成污染。 六、市场预测 城市排水设施是现代化城市不可缺少的重要基础设施,是城市正常运转的必要条件,城市排水设计水平的高低是一个城市现代文明的重要标志。 与发达国家甚至国内先进城市相比,q市的城市排水设施水平较为落后,主要体现在管材的使用上。虽然q市的排水体制是雨污分流制,但在管材的使用尤其是新型管材的使用上,却非常保守。近年来虽然q市排水基础建设项目较多,但所应用的管材却仍多为陶瓷管、混凝土管,鲜见新型管材的工程应用。这与q市飞速发展的经济状况是极不相称的。因此,应借鉴国内外先进城市的做法,逐步淘汰水泥管(混凝土管),大力推广使用新型管材。 根据《国家化学建材产业“十五”计划和2015年发展规划纲要》:塑料管的推广应用主要以UPVC和PE塑料管为主,并大力发展其它新型塑料管。2005年,在全国新建、改建、扩建工程中,建筑排水管道70%采用塑料管,建筑给水和热水供应管道60%采用塑料管,电线护套管80%采用塑料管,建筑雨水排水管道50%采用塑料管城市供水管道(DN400mm以下)50%采用塑料管,村镇供水管道70%采用塑料管,城市排水管道30%采用塑料管,城市燃气管道(中低压管)20%采用塑料管。 根据《q市市政建设“十五”计划及2010年发展规划》:“十五”期间,q市新、翻建市区雨、污水管道的投资为1亿元;2006~2010年,将新建、翻建雨、污水管网约100km,投资为07亿元。另外随着全国城市排水建设、污水处理及中水回用等投资力度的不断加大,q市本地以及全国市场对新型排水管材的需求将急剧增大,市场前景极为广阔。 七、技术经济比较 中空壁缠绕排水管与与水泥排水管相比较: 具有寿命长、无渗漏、通流量大、施工方便、工种综合费用节省等优势,列表分析如下: 1)以Ф600mm管为例,性能比: Ф600mm中空壁排水管(S≥8KN/m2) Ф600mm水泥管 产品性质 柔性管 刚性管 使用寿命 50年以上 20年 产品价格 490元/m 9元/m 工程综合造价 29元/m 31元/m 结构 受一定外压会弹性变形,但不会破坏 铺土不平造成管子破损 运输施工 重量轻、连接方便、搬运简便,8kg/m 弯曲分歧困难,笨重(260kg/m),施工耗力耗财,费用昂贵 连接方式 收缩模连接,塑料焊接加工连接 凹凸企口结合用水泥 理化性能 耐冲击、耐腐蚀、不漏水,耐寒性高,耐磨性强、寿命长 重量重,耐冲击低,受压易破损、漏水,耐化学性能差 破损率 柔性管,无破损 15% 发展趋势 建设部大力推广使用,市场呈上升趋势 落后淘汰,面临禁止使用 (注:工程综合造价一栏数据由上海市政提供) 八.结论与建议 与传统管材相比,新型塑料管材无论从技术性能指标、施工安装工艺还是综合经济比较,都是传统管材所不能比拟的。 在各种新型管材层出的今天,应尽快地出台相应的规章条文,对新型管材进行推广使用,并限制使用传统管材。 尽快地制订各种新型管材的行业规范及施工安装规范,以提高其技术及经济性指标,满足q市可持续发展方针的需要。仅供参考,请自借鉴。希望对您有帮助。

写一篇中文的,然后去有道翻译!

建筑给水排水论文3000字题目

写一篇中文的,然后去有道翻译!

2300字。你可以结合你学的知识稍微做一下修改。建筑给排水学习心得 水是人民生活、生产必备的资源。没有水源的建筑物是不具备使用功能的。作为建筑物必不可少的一部分,水又扮演着一个十分重要的角色。其中最基本,也是最重要的就是给水 、排水和消防工程。有的高档的小区有中水系统,可以直接把生活的污水加以利用。消防工程是为了在火灾的初期和中期对火灾加以控制,在消防车达到之先进行灭火。排水系统时将人们生活生产产生的污水废水排出建筑物,送到污水处理厂的一套系统。给水系统是为人民提供生产生活比不可少的水资源。在不同的地区、不同的小区里,不同的水,被送到个个房间里。一个完整的建筑物必不可少有给水排水系统和消防工程。下面我就我对这门课的心得体会,从给水方式,排水方式两方面谈一谈。 一.给水方式 建筑物的内部给水方式的选择应按以下原则进行;给水系统简单,管道长度短,安全可靠管理维修方便,外网的压力, 常见的给水方式有以下几种。 (1) 直接给水方式。建筑物内部有给水管道,部设有升压设备,直接由外网给水。这种给水方式简单,投资少,充分利用外网压力,安装维修方便。缺点系统无贮水设备。(2) 单设水箱给水方式。在建筑物的内部设有管道系统和屋顶水箱,且室内给水系统与室外的给水系统相连接。当室外外网的压力能够满足室内用水时,则由室外管网向室内给水,并向水箱供水,当用水高峰期时,室外的压力不足时,则由水箱向室内供水。这种供水方式的一定范围上解决了供水的不足。但是系统设置了水箱,增加了建筑物的结构荷载。(3) 水泵水箱联合给水方式。当室外水管网水压经常不足、室内用水不均匀、室外管网不允许直接有水泵吸水且建筑允许设水箱时,可以用这种给水方式。有了水泵的加入,工作效率提高了,增强了供水的可靠性。(4) 变频调速水泵给水。变频调速水泵的工作原理是当给水系统的流量变化时扬程也随着变化。这样的设备在一定程度上节约了电。(5) 分区给水方式。当建筑物大的高度增加到一定高度前面的给水方式都不适合。这时我们可以把建筑物的高度分成若干个区,分区给水分区以后产生一些弊端:管材零件配水器的费用增加。容易产生水锤及水锤噪声影响材料的使用寿命。高层建筑给水是建筑中比较特殊的。高度就是对给水系统是一种考验。高层建筑的给水方式有 1高位水箱 2无高位水箱 3气管给水。高位水箱又有三种方式1串联给水方式2并联给水方式3减压给水方式 无高位水箱的又有2种1串联给水方式2并联给水方式给水所用的管材:(1)镀锌钢管曾经是我过生活饮用水采用的主要管材由于其内壁容易生锈、结垢、滋生细菌、微生物等有害物质,会对自来水造成二次污染,可以采用焊接、螺纹连接、法兰连接或卡箍连接。优点是强度高、抗震性好。(2)不锈钢管优点机械性好、坚固、韧性好、卫生条件好。可采用焊接、螺纹连接、卡压式卡套式等连接。(3)铜管优点耐温、延展性好、承压能力好化学性质稳定、线性膨胀系数小。可用螺纹连接 、焊接、法兰连接。(4)应聚氯乙烯管优点:耐腐蚀好、抗老化性好价格便宜。通常采用承插粘接也可以用螺纹连接、法兰连接。(5)聚乙烯管优点:重量轻 韧性好 耐腐蚀 耐低温 良好的抗菌性 连接采用电熔热熔橡胶圈连接。(6)交联聚乙烯管交联聚乙烯管具有强度高 韧性好 抗老化(使用寿命50年以上)采用卡套式连接和卡箍式连接。目前,广泛采用新型建筑给水塑料管而淘汰镀锌钢管。铜管仍是高档住宅的首选,但价格高。一般在热水系统中采用带保温套的紫铜管、聚丁烯管(PB管)、铝塑复合管(PEX-AL-PEX)、PEX管、PPR管等。UPVC管和PE-AL-PE管适用于冷水供水系统。建筑物所用的给水管材和给水方式应该相匹配。这样才能使建筑材料发挥其实用功能,也可以使建筑物的成本减低。我觉得建筑的设计单位应该为业主考虑。 二.排水方式 高层建筑层数多,高度较大,多根横管同时向立管的几率较大,排水落差大,更容易造成管道中的压力的波动。因此高层建筑为了保证排水的通畅和通气良好,一般采用设置专门通气管系统。有的通气管的排水系统造价高,占地面积大。管道安装复杂,如果能省去通气管,对宾馆、写字间、住宅在美观和经济方面都是非常有益的。采用单了立管放大管径方式在经济和技术亦不合理。因此人们不断研究新的排水系统。影响排水立管通水能力的主要因素如下:1从横管流入立管的水流形成水舌阻碍气体,使空气难于进入下部管道造成负压。2立管中形成水塞阻碍空气流通。3水流到立管地步进入横管是产生水跃阻塞横管。(1)新型的排水系统:1苏维脱排水系统 1961年瑞士索摩研究发明了一种新型的排水立管配件,各层排水横管支管与立管采用水气混合气连接,排水立管采用气水分离器连接,这样达到取消通气管的目的,这种系统别称为苏维脱排水系统。 旋流排水系统 旋流排水系统 是法国的勒格、查理和鲁夫于1937年共同发明的。这种排水系统每层的横支管和立管采用旋流街头配件连接,立管底部采用旋流排水弯头连接。芯性排水系统 芯性排水系统是日本小道德厚于1973年发明的,在各层连接处设高奇马街头配件,在排水底部设角迪弯头。 (2)常用的排水管材 目前新建多层住宅均使用UPVC塑料排水管,室内UPVC排水管的类型有普通UPVC实壁管、UPVC芯层发泡管(PSP管)、UPVC螺旋消音管三种。普通UPVC实壁管噪音较大,而同等壁厚的UPVC芯层发泡排水管比UPVC实壁管重量轻约20%-30%左右,同时它又具有隔热隔音的效果,特别适合于建筑排水,可显着地降低流水噪音,大有取代UPVC实壁排水管的趋势。UPVC螺旋消音管不仅可以降低噪音,而且与其它同管径排水管相比排水能力大大提高。不仅可作为高层建筑的排水管,而且还不用设专用通气立管。因此,要根据安全、经济、环境等因素综合考虑,合理选择排水管

建筑设备给排水论文3000字怎么写

要:近些年来,建筑给排水的最大热点是新型管材的广泛应用。传统的镀锌钢管和普通排水铸铁管由于易锈蚀、自重大、运输施工不便等原因被取而代之。目前, 建筑给排水常用管材主要有塑料管,金属管和复合管三种。现在就常用管材的一些特性,优缺点,使用范围做一简要论述。关键词:建筑给排水 管材 塑料管 金属管 复合管塑料管塑料管是合成树脂加添加剂经熔融成型加工而成的制品。添加剂有增塑剂,稳定剂,填充剂,润滑剂,着色剂,紫外线吸收剂,改性剂等。常用塑料管有:硬聚氯乙烯管(PVC-U),高密度聚乙烯管(PE-HD), 交联聚乙烯管(PE-X),无规共聚聚丙烯管(PP-R),聚丁烯管(PB),工程塑料丙烯晴-丁二烯-苯乙烯共聚物(ABS)等。塑料管的原料组成决定了塑料管的特性。塑料管的主要优点:(1)化学稳定性好,不受环境因素和管道内介质组分的影响,耐腐蚀性好。(2).导热系数小,热传导率低,绝热保温,节能效果好。(3)水力性能好,管道内壁光滑,阻力系数小,不易积垢,管内流通面积不随时间发生变化,管道阻塞机率小。(4).相对于金属管材,密度小,材质轻,运输,安装方便,灵活,简捷,维修容易。(5).可自然弯曲或具有冷弯性能,可采用盘管供货方式,减少管接头数量。其主要缺点:(1)力学性能差,抗冲击性不佳,刚性差,平直性也差,因而管卡及吊架设置密度高。(2)阻燃性差,大多数塑料制品可燃,且燃烧时热分解,会释放出有毒气体和烟雾。(3)热膨胀系数大,伸缩补偿必须十分强调。所以,在推广塑料管的同时,还需要发展技术克服其缺点。1 塑料管性能1 物理性能:塑料管的物理性能和铝塑复合管,钢管,铜管比较见表1:表1物理性能 单位 PVC-U PE PE-X PP PB ABS 钢 铜 密度 g/cm 50 95 95 90 93 02 85 89 导热系数 w/mk 16 48 40 24 22 26 50 400 热膨胀系数 mm/m°C 07 22 15 16 13 11 012 018 弹性模量 MPa 3000 600 600 900 350 2500 210000 110000 拉伸强度 MPa 40 25 >25 28 17 40 700 150 硬度 R 120 70 100 60 230HB 使用温度 °C 0-60 -60-60 -60-95 -20-95 -20-95 -20-80塑料管的物理性能影响管道的方式,用途,补偿措施和管道保温等方面。如:(1)PVC-U、PP、ABS的力学性能相对较高, 被视为“刚性管”,明装较好。反之,PE、PE-X、PB作为“柔性管”适合暗敷。(2)塑料管的使用温度及耐热性能决定了PVC-U,PE,ABS仅能用于冷水管,而PE-X,PP, PB则可作为热水管。当建筑物有热水供应系统且冷热水采用统一管材时耐热性能成为主要指标。(3)塑料管因热膨胀系数高,在塑料管路中尤其是作为热水管,采用柔性接口,伸缩节或各种弯位等热补偿措施较多。其中以PE,PP等聚烯烃类为最。施工安装时如果对此没有足够重视,并采取相应技术措施,极易发生接口处因伸缩节而拉脱的问题。(4)由于导热系数低,塑料管的绝热保温性能优良进而可减少保温层的厚度甚至无需保温。当不同塑料管之间绝热性的比较除导热系数外,还同它们各自的管壁厚度有关。2 承压性能:承压性能所涉及的内容是在一定条件下塑料管材能够承受的内压力和恒压下的破坏时间。从而确定与之有关的设计参数以及对管材的质量进行评价和监控。一般进行两项试验:液压试验和长期高温液压试验。 各种管材的承压性能见表2表2管 材 工作压力/MPa 试样试验压力/MPa 接头密封试验/MPa 爆破压力/MPa UPVC 6 42/h De≤90,4.2PNDe>90,3.36PN PEX 0/95℃6/常温 5 6 ABS 0 8/h 4~8 PB 1.6~2.5/冷水0/热水 PP-RPP-C 0/常温6/75℃ 20℃,11h,16MPa80℃,48h,8MPa80℃,170h,2MPa HDPE 0/热水6/冷水3 卫生性能:理化卫生指标。其中PE,PE-X,PP,PB和ABS易达标。而PVC-U管材在生产时应使用无毒PVC树脂和卫生及稳定剂才能满足卫生性能的要求。2 给水塑料管的应用结构形式单一,材料品种众多且性能各异常用给水塑料管的特点列表如下:表3品种 优 点 缺 点 连接方式 PVC-U 抗腐蚀力强,易于粘合,价廉,质地坚硬 有UPVC单体和添加剂渗出,不适用于热水输送;接头粘合技术要求高,固化时间较长 粘合、螺纹 HDPE 韧性好,较好的疲劳强度,耐温度性能较好;质轻,可挠性和抗冲性能好 熔接需要电力;机械连接,连接件大 挤压夹紧、热熔合、电熔合 PEX 耐温性能好,抗蠕变性能好 只能用金属件连接;不能回收重复利用 挤压夹紧 PB 耐温性能好,良好的抗拉、压强度,耐冲击,低蠕变,高柔韧性 国内还没有PB 树脂原料,依赖进口,价高 挤压夹紧、热熔合、电熔合 PP-R 耐温性好 在同等压力和介质温度的条件下,管壁最厚 热熔合 ABS 强度大,耐冲击 耐紫外线差,粘接固化时间较长 粘合、螺纹、电熔合一般情况聚氯乙烯管由于价格低廉,在不考虑水质影响,在冷水供水系统属于首选管材,而当温度较高时,可选用聚乙烯管或交联聚乙烯管、聚丙烯管、聚丁烯管。3 排水塑料管的应用材质单一:硬聚氯乙烯结构形式多样:芯层发泡管,空壁管,螺旋管,芯层发泡螺旋管,空壁螺旋管。其存在的一些问题:(1)热膨胀系数大,需设置伸缩补偿装置来解决。(2)刚度小,平直性差,需加密管卡、支架、吊架来解决。(3)耐热性差,软化温度低,需限制排水温度,限制使用场所和控制与热源的距离来解决。(4)阻燃性差,在穿越楼板、上人屋面的屋面板、防火墙、管道井井壁处需设置阻火圈和防火套管来解决。(5)抗机械冲击性差,需强化施工技术,精心施工来解决。(6)隔声性差,塑料管的噪声大于铸铁管,管道明装且管道位置靠近卧室时,问题尤为突出。降噪的方式,提高管道材质的隔声效果,芯层发泡管空壁管是基于这一思路而开发的;降噪的另一方式是改变水流条件,螺旋管是基于这一思路而开发的。将两种方式结合起来的思路是芯层发泡螺旋管和空壁螺旋管的开发。相同条件下,不同结构形式的排水塑料管,其噪声测定结果:普通管>芯层发泡管>空壁管>螺旋管排水塑料管的应用是在取代普通排水铸铁管的工作上进行的。目前,排水塑料管已可在建筑高度为100m以下的建筑物内使用,但各地区的进展很不平衡。当建筑高度大于、等于100m的高层建筑和不适宜采用排水塑料管的场合,可采用柔性抗震排水铸铁管。[next] 金属管1 镀锌钢管镀锌钢管的被取代既不意味金属管被取代,也不意味镀锌钢管在整个建筑给水领域被取代。镀锌钢管由于价格低廉、性能优越,防火性能好,使用寿命长等优点,还将在消防给水系统,尤其是自动喷水灭火系统中应用而塑料管(承压小)则不应在消防给水系统和生活-消防,生产-消防共有系统中应用。2 铜管金属管中最具优势的是铜管,铜管应用较久,优点较多,管材和管件齐全,接口方式多样,较多的应用在热水管路中,目前存在的主要问题在于铜的折出量容易超标。3 铸铁管给水铸铁管与钢管相比有不易腐蚀、造价低、耐久性好等优点,适合于埋地敷设。缺点是质脆、重量大、长度小等。连接方式一般采用承插连接。卡箍式铸铁排水管是一种新型的建筑用排水管材,60年代开始进入国际市场,经过几十年的推广和应用,这种管材已得到国际上的普遍认可。这种管材与传统的承插式铸铁排水管道相比有许多优点,是一种更新换代产品,但由于这种管材及配件价格相对较贵,所以在国内一直未能得到普及推广。4 其它:不锈钢管也受到工程技术人员的青睐,有关方面正从减少壁厚,降低价格方面着手,以利于推广。铝合金管是铝厂向给排水行业推出的新品种。镀镍钢管是和镀锌钢管性质最近,而耐腐蚀性能远远超过镀锌钢管的新颖管材,在解决了降低镀层费用和管材断口处施工现场上镍工艺后,有望在一定范围内得到采用。涂塑钢管则是在金属管材中前景看好的一种管材,且管道布置和敷设、接口方式和施工安装均与镀锌钢管相同,是这种管材最容易被接受。由于其涂层薄、价格低,也最容易被推广。复合管:复合管包括衬铅管、衬胶管、玻璃钢管。复合管大多是由工作层(要求耐水腐蚀)、支承层、保护层(要求耐腐蚀)组成。复合管一般以金属作支撑材料,内衬以环氧树脂和水泥为主, 它的特点是重量轻、内壁光滑、阻力小、耐腐性能好;也有以高强软金属作支撑,而非金属管在内外两侧,如铝塑复合管,它的特点是管道内壁不会腐蚀结垢,保证水质;也有金属管在内侧,而非金属管在外侧,如塑覆铜管,这是利用塑料的导热性差起绝热保温和保护作用。根据金属的材料可分为:(1)钢塑复合管(2)不锈钢-塑复合管,塑覆不锈钢管(3)塑覆铜管(4)铝塑复合管,交联铝塑复合管(5)衬塑铝合金管应该说复合管材是管径≥300mm以上给排水管道最理想的管材。它兼有金属管材强度大,刚性好和非金属管材耐腐蚀的优点。但它又是目前发展较缓慢的一种管材。这是因为:(1)两种管材组合在一起比单一管材价格偏高。(2)两种材质热膨胀系数相差较大,如粘合不牢固而环境温度和介质温度变化又较剧烈,容易脱开,而导致质量下降。复合管的连接宜采用冷加工方式,热加工方式容易造成内衬塑料的伸缩、变形乃至熔化。一般有螺纹、卡套、卡箍等连接方式。由于复合管尚属新型管材,我国还未有统一的设计、施工及验收规范。设计及施工人员往往套用镀锌管的工艺来进行设计与施工,故在此不作一一赘述。

相关百科
热门百科
首页
发表服务