MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 1.给排水设计 饮用水和污水 Design Water and sewage water .设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 .Design bases Design Brief and Municipal integrated network drawing offered by the client. Condition drawings from architectural discipline. Current national design codes and related stipulations 2. 给水系统 通过一根DN200的进水管将水引入.水表安装在进水管上,离红线1米处.供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池.由环路管网向必需的室外消火栓和绿化带的喷淋器供水. 2. Water supply system For water supply of this project, DN200 water intake pipes are led in. Water meters are installed on the intake pipes m away from the red line. The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings respectively. Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop networks. 设计范围 包括红线内的饮用水,污水,雨水,建筑消防. Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red line. 给排水水池与消防水池分开,容量为100m3 .体操馆供水管埋地敷设. Sanitary water pool is separated from fire water pool, volume of sanitary water pool is 100m3. Water supply pipes for the stadium will be laid in the earth. 3.用水量标准 - 体育馆: 15升/顾客·日 K= - 宾馆: 150升/人·日 K= - 餐厅: 50升/顾客·日 K= - 工作人员: 25升/人·日 K= - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K= - Hotel: 150L/visitor·day K= - Restaurant: 50L/customer·day K= - Staff 25L/person·day K= - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water consumption. Unforeseen water consumption: 20% of the daily water consumption. Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: ·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机.为此饮用水系统安装循环泵.机房 设在地下室的水除了机房.当饮用水机不被使用时,应排空,以免水质腐败. 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵. 在更衣间旁设置电热水器,为淋浴和洗盥供应热水. 为楼板清洁安装一定数量的水龙头. Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the basement. When there is no use, portable water will be drained completely to avoid deterioration. Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot water. Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and washing. Certain number of water taps are installed for floor-cleaning. 4.用水量 最大日用水量:日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统.总冷却水用量为460m3/h.在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h).进水温度37Co,出水温度32Co .补充水量 9,6 m3/h.补充水由市政供水网直接提供. Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation system. Total water consumption of cooling towers is 460m3/h. On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/h. Make-up water of the cooling towers will be supplied directly by the municipal network. 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用).用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心. 消防水箱和消防稳压装置分别安装在车库的四面墙. In the fire water pump room, there are hydrant pumps (one operation, one standby), sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby). Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, etc. are provided in fire equipment centers. Four fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the garages. 消防用水 消火栓:室内按40升/秒,室外按30升/秒,火灾延续时间按3个小时计 自动喷洒按22升/秒,火灾延续时间按1小时计 卷帘水幕用水量 升/秒·米,火灾延续时间按3个小时计 消火栓:室内,室外用水量皆为756m3; 自动喷洒用水量为 m3; 卷帘水幕用水量为 270m3; 一次火灾用水量为; Water for fire protection Water consumption standard for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration is 3h Sprinkler: 22L/s, fire duration is 1h Drencher for rolling shutter: ·m, fire duration is 3h Water consumption for fire protection Hydrant: indoor and outdoor water consumptions are 756m3 respectively Sprinkler: m3 Drencher for rolling shutter: 270m3 Water consumption for one fire: m3 消火栓的布置 在整个建筑物内沿墙,沿柱,沿走廊,风塔上及楼梯附近设有必要数量的室内消火栓,消火栓间距小于30米.消火栓管网水平,竖向皆成环状布置,消火栓箱内配有DN65消火栓一支,25米衬胶水龙带一条,φ19毫米喷咀水枪一支,并配消防卷盘(DN25消火栓一支,30米胶管,φ9毫米喷咀水枪一支)且设有可直接启动消火栓泵的按钮;在室内消火栓箱下设有磷酸铵盐手提式灭火器箱.室内消火栓系统在室外设有三组水泵接合器. Hydrant arrangement Necessary number of hydrants are installed indoors along the wall, columns, corridors, and staircases, at intervals of less than 30m. Hydrant networks are connected as a loop both horizontally and vertically. Inside each hydrant box, a DN65 hydrant, a 25m long rubber lined hose, a water nozzle of φ19mm, hose reel (a DN25 hydrant, a 30m long rubber lined hose and a water nozzle ofφ9mm), and a direct starting button for the hydrant pump are provided. Under each indoor hydrant box, a portable ammonium phosphate powder extinguisher box is installed. There are three sets of pump adopters being installed outdoors for the indoor hydrant system. 消防系统 防水泵房及消防水池 供水管DN200在红线内连成环路管网,管网上安装 一定数量的消火栓.两根DN200供水管分别引入供应楼内两个消防泵房内的消防水池.消防水池总容量不应小于4000m3, 每个为. Fire protection system Water pump room and water pool for fire protection The lead-in pipes (DN200) are connected as a loop inside the red line, on the loop, certain number of hydrants are water supply pipes (DN200) are led into the fire water pools at each fire water pump room in supplybuilding. In consideration of the importance of the project, the volume of the fire water pools should be not less than 4000m3, each is . 自动喷淋系统 自动喷淋系统安装在全建筑范围,除了室外和高于10 米的房间.喷淋泵安装在地下的消防泵房内.报警阀设置在地下的消防泵房内和中间的消防设备中心内,水流显示器设在每个防火分区内. Sprinkler system Sprinkler systems will be provided inside the whole building except outside areas and roomshigher than 10m, with sprinkler pumps installed in the underground fire water pump rooms. Alarming valves installed in underground fire water pump rooms and four fire equipment centers in the middle, water flow indicators are installed by fire compartments. 除了安装一个封闭喷淋系统,将为地下车库设置一个泡沫喷淋系统.餐厅内安装93oC启动的自动喷淋头,但在其它房间,仅安装93oC启动的普通和快速反应自动喷淋头.三组泵接合器安装在室外. Besides an enclosed sprinkler system, a foam sprinkler system composed of a proportioning mixer and a foam concentrated tank is provided for the underground garage. Sprinkler actuated at 93oC are provided in the restaurants, but in other rooms, only ordinary sprinklers and fast response sprinklers actuated at 68oC are provided. Three sets of pump adaptors for this system will be installed outdoors. 排水系统 为排水系统设置污水主立管和特别垂直排气管.排气管与污水管在每层连接,污水排出体操馆.餐厅的污水首先在油脂分离池中处理,然后排入室外排水网.给排水污水将被在化粪池收集和处理,然后排入市政排水管网.化粪池在输送区旁.最大天排水量为870m3/天. 9. Drainage system Main vertical sewage pipes and special vertical vent pipes are provided for the drainage system. The vent pipes are connected with sewage pipe at each floor; sewage water is drained out of stadium. Sewage water in the restaurants and garage are treated in the grease and oil separation tank, and then discharged into the outdoor drainage networks. Sanitary sewage water is collected and treated in the septic tank, then drained into the municipal drainage. The septic tanks are located besides the deliverycircle. Maximum daily drainage amount is 870m3/day. 卷帘水幕系统 地下车库设置有卷帘水幕系统.水幕泵安装在消防水泵房内,采用开式雨淋头,电动或手动控制.十组泵接合器安装在室外 Drencher system for rolling shutters Rolling shutter protected by drenchers are provided for the underground garage, the drencher pumps are installed in the fire water pump rooms, open drencher heads are selected, and are controlled both by electrically and manually. Ten pump adapters will be installed outdoors for this system. 地下室内污水设有污水坑,废水设有废水坑,生活污水,废水经潜污泵提升排至室外排水管网,潜污泵的启停皆由磁性浮球控制器的控制. 地下汽车库废水设有废水坑,废水经潜污泵提升排至室外,经隔油池处理后排入室外雨水管网. There are cesspits for sewage water and wastewater pits for wastewater in the basement, the sewage and wastewater is sucked up and drained to the outdoor drainage networks by submerged sewage pumps. Operation of the pumps is controlled by the magnetic floating ball controllers. Wastewater pits are provided for the underground garage, wastewater is sucked up and drained to outdoor oil separation tank by submerged sewage pumps, after treated, wastewater is drained to the outdoors rainwater networks. 在柴油发电机房,变配电房和通讯设备机房设低压二氧化碳气体灭火系统. Low pressure CO2 extinguisher systems are provided in diesel generator rooms, transformer substations and telecommunication equipment rooms. 在本建筑内按"建筑灭火器配置设计规范"在每个消火栓箱下设手提式灭火器箱,箱内设有必要数量的磷酸铵盐手提式灭火器. According to the Code for Design of Extinguisher Disposition in Buildings, portable fire extinguisher box, in which there are necessary number of portable ammonium phosphate powder extinguishers, will be installed under every hydrant box. 在每个消防电梯井底旁设有消防排水坑,废水经潜污泵提升排至室外. Fire water drain pit is provided at side of bottom of each fire elevator well, waste water will be sucked up and drained out by the pumps. 雨水系统 雨水排水屋顶采用压力流排水. 雨水设计重现期按P=10年计算,降雨历时为5分钟,暴雨强度公式按Q=(1+)/(t+)计算. 沿柱在屋面设置雨水沟.雨水通过雨水沟收集,然后进入雨水头和下排管,然后到室外雨水观察井. 10. Rainwater system Pressurized drainage system is adopted for roof rainwater drainage system. Here, return period P=10 years, rainfall duration is 5 minutes, stormwater amount is calculated by the following formula: Q=(1+)/(t+) Rainwater gutters are provided on roof along columns, skylight. Rainwater is collected in the gutter, then to rainwater heads and downpipes, and to the outdoors rainwater inspection wells. 11.管材 - 生活给水管,冷却塔补水管采用铜管,氩弧焊接. - 直饮水管采用不锈管. - 消火栓管,冷却循环管,水幕管,水泵吸水管采用焊接钢管,焊接. - 自动喷洒水管,雨淋水管采用热镀锌钢管,丝扣连接或卡压连接. -二氧化碳管采用无缝钢管焊接. - 地下车库泡沫喷淋水管采用不锈钢管,卡压连接. Pipe material Copper pipes connected by argon arc welding are adopted for the sanitary water pipes, make-up water pipes for cooling towers. Stainless stell pipes are adopted for portable water pipes. Welded steel pipes connected by welding are selected for hydrant pipes, cooling circulating pipes, drencher pipes, pump suction pipes. Hot-galvanized steel pipes connected by threads or compression-seizing are selected for sprinkler and deluge sprinler pipes. Seamless steel pipes connected by welding are selected for CO2 pipes. Stainless steel pipes connected by pressed clamp is selected for the pipes of foam sprinklers in the underground garage. 当雨水两超出雨水沟设计量时,雨水可沿屋檐自由排放.雨水被收集,然后排入市政集水池. When the amount of rainwater is more than the design value of the gutters, water is discharged naturally along the eaves. Rainwater is collected, and then drained to the municipal catch basins. 围绕体育馆的循环池将用于喷洒运动场和作为室外绿化带的储水池. 此池将作为一个循环过滤设施,可容水约 m . 喷洒压力设备和其它必须的过滤设备安装在供应楼里. The circular senic pool surround stadium will be used for spraying sportsfield and as reservoir for outdoor greening. The pool will be used as a circular filtering facility and will be adopted with a water volume of about m . The spray water pressurizing equipment as well as further necessary filtering equipment will be adopted in the supply building. 制冷 Cooling 冷源: 空调冷负荷(估算): 本工程建筑面积共平方米,包括观众区,休息室,更衣室,小会议室,餐厅,办公室和其它附属房.空调设计日峰值冷负荷为,设计日总冷负荷为3 kW. Refrigerating source Cooling load of air conditioning system Total floor area for this building is 50,000sqm, which includes spectator areas, lounges, Clothing and changing rooms small meeting rooms, restaurant, office and other auxiliary rooms. Designed dayly peak cooling load is 2,4MW, designed total dayly cooling load is 3kW. 每台1200kW制冷机配一台 流量为206m3/h离心泵.各配一台备用泵 一次泵采用压差旁路控制. 通过埋地敷管,向游泳体操馆供应冷冻水. A centrifugal pump with a flow rate of 103m3/h is provided for each 1200kW chiller. One operation pump with a standby corresponds to one chiller. Pressure difference branch control is adopted for primary pump Via earth laid pipes from supply building to gymnasium chilled water supply will be deliverded. 冷源的选择: 根据建筑的实际情况,3台制冷机将安装在供应楼内的冷冻机房.设计容量为4800kW. 为了实现能量的效率化使用,设计方案为,1台制冷机的出力为总设计容量的50%.而另2 台.每台出力为总设计容量的25%. 冷冻水系统的主要设备包括3台电动制冷机,一级冷冻泵,二级冷冻泵,自动控制阀等等.冷冻水的供/回水温度为-7/ 12°C. Selection of refrigerating source According to the real condition of the building, 3 chillers are located in the refrigerating plant rooms in the supply building, designed capacity is 2400kW. For actuing in an energy efficient way one chiller about 50% of total capacity ( kW) and two chillers with 25% of total (600 kW each)capacity each are adopted. Main equipment of chilled water system includes 3 electrical chiller, primary cool water pump, secondary chilled water pump and automatic controlled valve, etc. supply/return temperature of the chiller is-7/ 12°C. 二次泵系统:根据使用功能,各制冷机房又分成不同的循环支路. 二次泵采用变频调速控制.根据负荷侧供回水管的压差,控制水泵的转速. 二次泵循环支路的管道采用异程式. Secondary pump system: Each refrigerating plant room is subdivided into different circulation branch loops according to use functions. Variable-frequency speed-regulating control is adopted for secondary pumps. The rotating speed of a water pump is controlled according to the pressure difference between water supply and return pipes. Direct return system is adopted for the pipes of circulating branch of secondary pumps 空调冷冻水系统 由于本工程占地面积大,功能复杂,有连续使用,也有间歇使用,为了达到运行灵活,节能的目的,空调冷冻水系统采用两管制二次泵系统. Chilled water system Due to the large occupied area of this project, the complicated functions and the combination of continuous utilization and intermittent utilization, in order to accomplish the purpose of flexible operation and energy saving, the chilled water system is of two-pipe secondary pump system. 管材: 水管采用焊接钢管及无缝钢管. 本工程的风管除土建风道外,均采用镀锌铁皮咬口制作.每节风管之间用法兰连接. Pipe and duct materials The water pipes adopt welded steel pipes and seamless steel pipes. Air ducts for this project are made of galvanized sheet steel by seaming except ducts by civil construction. Air ducts are connected together by flanges. 一次泵系统: 供应楼冷冻机房 2400kW制冷机配一台离心泵, 流量为412m3/h.配一台备用泵. Primary pump system: Chiller room supply building A centrifugal pump with a flow rate of 412m3/h is provided for 1200kW chiller. One operation pump with a standby corresponds to one chiller. 保温材料: 空调供,回水管,冷凝水管采用酚醛管壳保温. 空调送,回风管以及处理后的新风管采用外贴铝箔的离心玻璃棉板保温. - 管道穿防火墙的空隙处采用岩棉材料等非燃材料填充. Thermal materials phenolic pipes are adopted for thermal insulation of water supply and return pipes for air conditioning, as well as air-conditioning condensate pipes. Aluminum foil faced glass fiber boards are adopted for thermal insulation of air-conditioning air supply and return ducts as well as fresh air ducts after chillers. Non-flammable material will be selected to fill the interspace in the fire protection wall where the ducts go through. 消声与隔振: 冷水机组,水泵等设备采用减振台座,弹簧减振器或橡胶减振垫减振降噪. 在空调机组,新风机组,通风机的进出口采用涂胶帆布软管连接. - 水泵进出水管上采用可曲挠橡胶接头,使设备振动与配管隔离. Noise reduction and vibration isolation Shock absorption bases, spring shock absorbers on rubber shock absorption pads are adopted for equipment, such as water chiller units, pumps, etc to reduce vibration and lower noise. Flexible rubber-coated canvas hoses are adopted far connections of inlets and outlets of air-conditioning units, fresh air handling units and ventilators. Flexible rubber couplings are adopted for the water intake and delivery pipes of the pumps to isolate equipment vibration from their pipes. 空调和通风系统 Air Conditioning and Ventilation Systems 方案设计范围 Scope of schematic design 空调设计 Air Conditioning Design 在体育馆内,一些区域设置空调系统.这些区域划分为: 西侧地下二层的贵宾休息室 东侧地下二层酒店门廊 地下一层的输送区,技术机房,运动员更衣间,医务服务,热身区,裁判区,健身中心,酒店大堂,会议室,厨房,特许区和贵宾大堂混合区. 首层的酒店大堂,酒店区,贵宾门廊,急救 In the stadium, in some ranges air conditioning systems are used. These ranges subdivide themselves as follows: VIP – Lobby in West of levelel -2 Hotel lobby in the east of level –2 Delivary Circle, technical Plantrooms, Changingrooms for the athletes, Medical Service and warm up area, Judges Area, Fitness Center, Hotel Lobby, Conferenz, Kitchen and Concession, Vip lobby- Mixed Zone in level -1 Hotel lobby, Hotel area, Vip lobby, Vip Area, First aid in 0

2)多年来我国《建筑给水排水设计规范》中的给水设计秒流量计算公式一直沿袭平方根法,计算某些建筑物时计算数值偏大,存在明显缺陷和不足。如我们按照目前美、俄等国在计算给水设计秒流量时采用的概率法计算,又因中国人的生活习惯、饮食结构不同,其计算结果也不合理、不科学。因此,目前国内科研工作者对现行的给水设计秒流量计算公式提出了多种修改、修正式,以弥补原计算公式的欠缺和不足。这些新的修正式,结合实践试算,其结果比原计算公式接近用水的实际工况,宏观上步入了概率的计算方法,但现尚缺乏概率法涉及的计算参数,如高峰期用水定额、高峰期时段历时、用水保证率、传统生活习惯和饮食结构等诸多影响计算式结果的因素,所以采用符合国情的概率法计算给水设计秒流量的工作尚需作大量的调查、统计和科研工作。� 2 开展建筑给水水质保障技术研究� (1)提高了生活饮用水水质标准。随着国家经济实力地增长,卫生部修改了1985年制定的GB5749-85《生活饮用水标准》。修改后标准的相关指标比原水质标准有了较大的提高,如浊度由3 NTU提高到1 NTU;新增了一个对水中总有机物量的限值指标——耗氧量(以CODmn表示),限值为3 mg/L。“标准”提高了,意谓原水处理程度提高、资金投入增加,涉及面较多,需协调处较多。目前,该标准是卫生部发布的。据说,对“标准”规定的水质指标及其带来的各种问题,各部委之间认识还不统一。� (2)为了与各种瓶装商品水,各种功能水区别,同时也从国情出发,建设部制定了CJ94-1999《饮用净水水质标准》行业标准并已于2000年3月1日起实施。一段时期以来,各种水商品充斥市场。喝什么水好,什么水有益于人体健康?众说纷纭,莫衷一是。相信《饮用净水水质标准》的颁布与实施将有利于居高和生活饮用水管道分质供水工程的正常发展。由中国建筑设计院、清华大学等5个单位承担的建设部《建筑及居住小区优质饮用水供应技术》科研课题已经完成,除上述水质标准成果外,在净化工艺及净水机开发、自动控制、系统设计秒流量公式推导及系统设置、管材、管件等方面均取得了突出成果。� (3)国家科委、建设部设立“建筑(居住)区内水质状况调查分析及水质污染途径”的研究课题,并且取得了积极成果。根据污染途径的研究,采用如下防止生活饮用水二次污染的具体措施,是课题成果之一。� ①淘汰钢筋混凝土和钢板水箱。推荐使用FRP水箱、搪瓷钢板水箱、不锈钢水箱及复合钢板水箱。目前市场上又出现自动开闭水箱、充气密闭水箱等新型卫生水箱。� ②为减少二次污染途径,推荐采用变频调速供水系统,取消传统高位水箱。� ③如条件允许,推荐直接从市政干管吸水,采用变频调速供水系统,取消贮水池,不仅充分利用了市政供水压力,还消除了水的二次污染源。� ④推荐选用水质保障设备,如除氟、除铁、除锰设备;推荐选用多种饮用净水设备,如臭氧、活性炭、微滤、超滤纳滤及KDF活性炭、陶瓷过滤等终端处理设备。� ⑤推荐选用多种防二次污染的消毒设备,如臭氧、二氧化氯、次氯酸钠及紫外线等处理设备。� ⑥推荐选用防水质污染的新型给水管道(详见本论文3)、管道附件如倒流防止器等。� 3 积极开展新型管材、管件研究和推广� 建筑住宅内给水管道采用传统的镀锌钢管已有近百年的历史,镀锌钢管对中国自来水行业的发展作出了突出贡献。但随着经济的迅猛发展,人们的生活质量不断提高,对自来水的水质要求也日趋提高。人们对自来水的“红水”、“黑水”等现象反映强烈。导致管网水质恶化的主要原因是建筑物内给水管道的锈蚀严重。冷镀锌钢管一般使用寿命不到la就锈蚀,铁腥味严重。从个别用户水龙头的水样分析化验中得知,细菌总数、大肠菌群严重超标,居民纷纷向政府部门投诉,造成一种社会问题。� 20世纪80年代以前,建筑(住宅)内排水管道主要采用手工砂模承插排水铸铁管,该管材生产方法劳动强度大,生产效率低,产品质量差,影响周边环境质量,也是急待治理的社会问题。 鉴于上述情况,建设部、国家经贸委、国家质量技术监督局和国家化学建材局于1999年12月联合颁布了“建住房〔1999〕295号”文《关于在住宅建设中淘汰落后产品的通知》,文中规定:自2000年6月1日起,在城镇新建住宅中,淘汰砂模铸造排水管用于室内排水管道,推广应用硬聚氯乙烯(PVC-U)塑料排水管和符合《排水用柔性接口铸铁管及管件》(GB/T12772-1999)的柔性接口机制铸铁排水管;禁止使用冷镀锌钢管用于室内给水管道,并根据当地实际情况逐步限时淘汰热浸镀锌钢管,推广应用铝塑复合管、交联聚乙烯(PE-X)管、三型无规共聚聚丙烯(PP-R)管等新型管材。伴随这一政策的出台,市场上也涌现出多种管材,如薄壁铜管、薄壁不锈钢管、PVC-U、CPVC、PE、HDPE、PE-X、PAP、PP-H、PP-B、PP-R、PB、ABS、FRP、各种钢塑复合管及柔性排水铸铁管等。各种管材群雄割据、并驾齐驱。与新型管材配套的管接头,品种繁多、结构和选材各异,各厂家质量参差不齐。各种新型管材和管件虽有良好的发展机遇,但在市场经济条件下,他们能否保持强大的生命力将由建材市场检验。4 积极推广节水节能技术� 水资源匮乏已成为制约我国经济发展的瓶颈。节约能源是我国的国策。在建筑给水排水中,节能节水技术得到了较大的推广与突破。� (1)水资源匮乏地区加强污水资源化和提高水的复用率。中水按回用对象及水质要求,其处理工艺已由传统的二级生化法,发展到三级处理(即增加了过滤和消毒),对要求高的复用水水质,如作为饮用水水源和补充水,可采用高级深度处理工艺,如微滤、反渗透等处理方法;雨水截留、利用技术和建设生态小区,利用湿地处理雨水和生活污水的研究已到工程应用 阶段。� (2)淘汰了升降式铸铁水嘴,推荐采用陶瓷片密封水嘴,推荐公共场所采用感应式或延时自闭式水嘴。� (3)淘汰了9L以上冲洗水箱,推荐采用6L的冲洗水箱。开发了多种节水型卫生洁具和配件,如无冲洗水箱的喷射式便器。� (4)各种高精度的干、湿式水表、IC卡水表、远传水表及用于饮用净水系统,精度达1L/h的远传干式水表等均已问世,且一定要安装分户水表计量考核,既方便了居住区物业管理和居民生活,也杜绝了水资源的浪费。� (5)各种循环冷却水系统的研究成果广泛应用在空调系统中,如射流式冷却塔和喷雾式冷却塔的开发;各种水质稳定剂的研究及系统的智能化控制等也取得较好的进展。� (6)利用海水冲厕。� (7)供水压力应减压至~。� (8)建筑热水系统中对各种热(能)源的开发取得了显著成效。加强余热利用,推荐使用电源。地热和太阳能研究成果已用于工程中。目前,我国已成为全世界太阳能热水器年销售量第一的国家。各种新型间接加热设备已广泛用于集中热水供应系统,如汽——水、水——水换热的浮动盘管式或波节管式半容积和半即热式及板式水加热器及燃油燃气热水机组等。� (9)热水系统水泵、阀门、配套附件等产品开发均取得较大进展,如,平均无故障工作时间达8000h热水泵的问世、各种高灵敏度的温控阀的研制成功等。� (10)从节水、节电、节地角度,开展建筑热水系统模式研究,如干管、支管循环,电伴热热水供应系统研究均取得了一定成果。同时探讨合适的热水供应温度,既能缓解结垢和腐蚀、节能节水,同时又能抑制热水中军团菌等的滋生。 5 建筑给水、建筑热水设备技术热点简介� (1)供水设备:� ①微处理器,实现电机软启动、软制动、节能;� ②变频器自带PLC;� ③直接自市政供水干管吸水、无吸程、无负压、节能;� ④射流泵辅助变频调速供水、节能;� ⑤带有触摸屏的可视化控制;DCS控制系统;� ⑥美观、一体化、、不锈钢化;� ⑦水箱密闭、自动呼吸;� ⑧符合GB/T17219;� ⑨各种优质水处理机组。� (2)热水设备:� ①浮动盘管换热器改进型,如单元组合式、一壳多管式换热器,换热量大,占地面积小; ②波节管、波纹管换热器,传热系数大;� ③当热媒不回收时,直混式换热器,换热效率高;� ④地热技术;� ⑤太阳热水器及其辅助设备;� ⑥管壳式、半即热式、半容积式、容积式及板式换热器共荣共存、分别适应不同工况。 ⑦温度控制阀,精度、价格;� ⑧换热设备的检修、传热元件的振动、磨损脱焊和积垢;� ⑨对半即热式换热器是否设有温度、压力双控制的安全措施。� 6 美化环境、隔振降噪� 治理、保护和美化环境,维持生态平衡是可持续发展的关键。� (1)作为城市景观的重要标志——大型多功能喷泉,如彩色音乐喷泉、激光水幕电影、趣味游戏旱泉等等,在全国各大城市涌现,她集中了水工艺、建筑、动画、声光、机械、自控等多种学科的先进技术。水景喷泉技术的发展对丰富人民文化生活、创造优美生活环境作出了重大贡献。� (2)城市绿地、花园草坪的喷洒工艺出现多种形式喷头,并可通过GPS自动定位和PLC自动控制。� (3)水泵、管道隔振降噪技术已有成熟的工程经验。� (4)为克服塑料排水管噪声大的缺憾,开发出许多新产品,如PE静音排水管、芯层发泡管、螺旋形芯层发泡排水管等,不仅可作单立管排水增大排水流量,同时也可以大幅度降噪。� 7 建筑消防技术方面应用的动态� (1)在消火栓仍作为建筑物消防的主要手段前提下,加强了自动喷淋灭火的力度,为其向消防主体过渡打下了基础。自动喷水灭火系统,是当今世界上公认的最有效的自救灭火设施,是应用最广泛的自动灭火系统。原GBJ84-85《自动喷水灭火系统设计规范》自1985年颁布执行以来,对指导系统的设计,发挥了良好的作用。但随着新技术新情况和新问题不断涌现,公安部会同有关部门修编了该规范,并自2001年7月1日起施行。新规范编号为GB50084-2001。该规范的问世对我国自救式消防技术的充实与完善是一重大进步。� (2)消防泵有了行业标准,规范了消防泵生产。切线泵以其恒压变流量特性引起业内人士极大关注。� (3)《建规》、《高规》、《建筑内部装修设计防火规范》和《人民防空工程设计防火规范》进行了局部修订。为了不断总结经验教训,遏制公众聚集场所,特别是公共娱乐场所和地下商场火灾事故的发生,保护人身财产安全,公安部经商建设部同意对上述四项国家标准进行了局部修订。自2001年5月1日起施行。此次局部修订的条文内容均为强制性条文。� (4)自从国家要求限制和逐步淘汰卤代烷灭火剂、灭火器和灭火系统以来,究竟用哪一种替代物取代卤代烷,至今国家未给出明确技术法规,相关的“气体灭火设计、施工及验收规范”尚未出台。但研究工作,试点工作,在各地方消防部门的积极支持下,已取得了一定的成果,并已应用到工程中。� 8 大屋面雨水排除技术的重大进步� 屋面雨水排除,特别是对大面积车间、厂房屋面雨水排除,经技术经济比较后认为采用内排水时,按传统的重力法计算方法,宜采用单头排水,如采用多斗时,最多不能超过4个。按该计算要求,既使对缺雨的北方大屋面雨水排除,也要有多条雨水悬吊管和立管,除要消耗大量金属管材外,对车间、厂房设备的布置和生产均有较大影响。目前,在中外合资大跨度机库、大剧场、大车间屋面雨水设计中,采用了压力式(虹吸式)雨水斗,采用压力法计算方法,结束了单斗排水或最多4斗排水系统,摒弃了传统的重力法计算方法,使大面积屋面雨水内排水的悬吊管不受雨水斗数量限制,不受坡度限制。压力式(虹吸式)雨水斗的出现和压力法的计算方法的采用,是一重大的技术进步。� 9 积极开展技术和产品的规范、标准、标准图的制定、宣传和执行工作� (1)宣传、学习、贯彻执行有关强制性规范、标准,对工程质量的保障起了重大作用。 (2)《建筑给水排水设计规范》、《游泳池设计规范》、《中水设计规范》、《给水排水制图标准》等国家和行业规范正在修编。� (3)按照“多出、快出、出好”的要求,各种给水排水设备产品的行业标准,如PP-R管、PE管、PAP管、薄壁不锈钢管、径向加筋PVC-U排水管、倒流防止器及地漏等标准及其设计、施工验收规范将陆续颁发执行。� (4)在建设部成立了全国工程建设标准设计领导小组,下设给水排水标准设计委员会、组织编(修)各种国家标准图,提高工程质量和设计效率。 建筑给排水技术是水工业中的一个重要分支,她的发展是与社会进步、国力增强密切相关的。建筑业,尤其是住宅产业的发展,是拉动国民经济新的增长点的支柱产业之一,申奥成功、加入WTO、2008年在北京主办奥运会,为建筑给排水技术的发展提供了绝好的机遇和广阔的市场。我们坚信21世纪是高新科技发展的世纪,是贯彻以人为本、注重环保的世纪,随着国民经济的发展和人民生活水平的提高,建筑给排水技术这支奇葩将会绽放得更加绚丽多彩。

建筑给水排水设计论文

MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 1.给排水设计 饮用水和污水 Design Water and sewage water .设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 .Design bases Design Brief and Municipal integrated network drawing offered by the client. Condition drawings from architectural discipline. Current national design codes and related stipulations 2. 给水系统 通过一根DN200的进水管将水引入.水表安装在进水管上,离红线1米处.供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池.由环路管网向必需的室外消火栓和绿化带的喷淋器供水. 2. Water supply system For water supply of this project, DN200 water intake pipes are led in. Water meters are installed on the intake pipes m away from the red line. The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings respectively. Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop networks. 设计范围 包括红线内的饮用水,污水,雨水,建筑消防. Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red line. 给排水水池与消防水池分开,容量为100m3 .体操馆供水管埋地敷设. Sanitary water pool is separated from fire water pool, volume of sanitary water pool is 100m3. Water supply pipes for the stadium will be laid in the earth. 3.用水量标准 - 体育馆: 15升/顾客·日 K= - 宾馆: 150升/人·日 K= - 餐厅: 50升/顾客·日 K= - 工作人员: 25升/人·日 K= - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K= - Hotel: 150L/visitor·day K= - Restaurant: 50L/customer·day K= - Staff 25L/person·day K= - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water consumption. Unforeseen water consumption: 20% of the daily water consumption. Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: ·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机.为此饮用水系统安装循环泵.机房 设在地下室的水除了机房.当饮用水机不被使用时,应排空,以免水质腐败. 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵. 在更衣间旁设置电热水器,为淋浴和洗盥供应热水. 为楼板清洁安装一定数量的水龙头. Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the basement. When there is no use, portable water will be drained completely to avoid deterioration. Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot water. Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and washing. Certain number of water taps are installed for floor-cleaning. 4.用水量 最大日用水量:日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统.总冷却水用量为460m3/h.在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h).进水温度37Co,出水温度32Co .补充水量 9,6 m3/h.补充水由市政供水网直接提供. Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation system. Total water consumption of cooling towers is 460m3/h. On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/h. Make-up water of the cooling towers will be supplied directly by the municipal network. 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用).用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心. 消防水箱和消防稳压装置分别安装在车库的四面墙. In the fire water pump room, there are hydrant pumps (one operation, one standby), sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby). Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, etc. are provided in fire equipment centers. Four fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the garages. 消防用水 消火栓:室内按40升/秒,室外按30升/秒,火灾延续时间按3个小时计 自动喷洒按22升/秒,火灾延续时间按1小时计 卷帘水幕用水量 升/秒·米,火灾延续时间按3个小时计 消火栓:室内,室外用水量皆为756m3; 自动喷洒用水量为 m3; 卷帘水幕用水量为 270m3; 一次火灾用水量为; Water for fire protection Water consumption standard for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration is 3h Sprinkler: 22L/s, fire duration is 1h Drencher for rolling shutter: ·m, fire duration is 3h Water consumption for fire protection Hydrant: indoor and outdoor water consumptions are 756m3 respectively Sprinkler: m3 Drencher for rolling shutter: 270m3 Water consumption for one fire: m3 消火栓的布置 在整个建筑物内沿墙,沿柱,沿走廊,风塔上及楼梯附近设有必要数量的室内消火栓,消火栓间距小于30米.消火栓管网水平,竖向皆成环状布置,消火栓箱内配有DN65消火栓一支,25米衬胶水龙带一条,φ19毫米喷咀水枪一支,并配消防卷盘(DN25消火栓一支,30米胶管,φ9毫米喷咀水枪一支)且设有可直接启动消火栓泵的按钮;在室内消火栓箱下设有磷酸铵盐手提式灭火器箱.室内消火栓系统在室外设有三组水泵接合器. Hydrant arrangement Necessary number of hydrants are installed indoors along the wall, columns, corridors, and staircases, at intervals of less than 30m. Hydrant networks are connected as a loop both horizontally and vertically. Inside each hydrant box, a DN65 hydrant, a 25m long rubber lined hose, a water nozzle of φ19mm, hose reel (a DN25 hydrant, a 30m long rubber lined hose and a water nozzle ofφ9mm), and a direct starting button for the hydrant pump are provided. Under each indoor hydrant box, a portable ammonium phosphate powder extinguisher box is installed. There are three sets of pump adopters being installed outdoors for the indoor hydrant system. 消防系统 防水泵房及消防水池 供水管DN200在红线内连成环路管网,管网上安装 一定数量的消火栓.两根DN200供水管分别引入供应楼内两个消防泵房内的消防水池.消防水池总容量不应小于4000m3, 每个为. Fire protection system Water pump room and water pool for fire protection The lead-in pipes (DN200) are connected as a loop inside the red line, on the loop, certain number of hydrants are water supply pipes (DN200) are led into the fire water pools at each fire water pump room in supplybuilding. In consideration of the importance of the project, the volume of the fire water pools should be not less than 4000m3, each is . 自动喷淋系统 自动喷淋系统安装在全建筑范围,除了室外和高于10 米的房间.喷淋泵安装在地下的消防泵房内.报警阀设置在地下的消防泵房内和中间的消防设备中心内,水流显示器设在每个防火分区内. Sprinkler system Sprinkler systems will be provided inside the whole building except outside areas and roomshigher than 10m, with sprinkler pumps installed in the underground fire water pump rooms. Alarming valves installed in underground fire water pump rooms and four fire equipment centers in the middle, water flow indicators are installed by fire compartments. 除了安装一个封闭喷淋系统,将为地下车库设置一个泡沫喷淋系统.餐厅内安装93oC启动的自动喷淋头,但在其它房间,仅安装93oC启动的普通和快速反应自动喷淋头.三组泵接合器安装在室外. Besides an enclosed sprinkler system, a foam sprinkler system composed of a proportioning mixer and a foam concentrated tank is provided for the underground garage. Sprinkler actuated at 93oC are provided in the restaurants, but in other rooms, only ordinary sprinklers and fast response sprinklers actuated at 68oC are provided. Three sets of pump adaptors for this system will be installed outdoors. 排水系统 为排水系统设置污水主立管和特别垂直排气管.排气管与污水管在每层连接,污水排出体操馆.餐厅的污水首先在油脂分离池中处理,然后排入室外排水网.给排水污水将被在化粪池收集和处理,然后排入市政排水管网.化粪池在输送区旁.最大天排水量为870m3/天. 9. Drainage system Main vertical sewage pipes and special vertical vent pipes are provided for the drainage system. The vent pipes are connected with sewage pipe at each floor; sewage water is drained out of stadium. Sewage water in the restaurants and garage are treated in the grease and oil separation tank, and then discharged into the outdoor drainage networks. Sanitary sewage water is collected and treated in the septic tank, then drained into the municipal drainage. The septic tanks are located besides the deliverycircle. Maximum daily drainage amount is 870m3/day. 卷帘水幕系统 地下车库设置有卷帘水幕系统.水幕泵安装在消防水泵房内,采用开式雨淋头,电动或手动控制.十组泵接合器安装在室外 Drencher system for rolling shutters Rolling shutter protected by drenchers are provided for the underground garage, the drencher pumps are installed in the fire water pump rooms, open drencher heads are selected, and are controlled both by electrically and manually. Ten pump adapters will be installed outdoors for this system. 地下室内污水设有污水坑,废水设有废水坑,生活污水,废水经潜污泵提升排至室外排水管网,潜污泵的启停皆由磁性浮球控制器的控制. 地下汽车库废水设有废水坑,废水经潜污泵提升排至室外,经隔油池处理后排入室外雨水管网. There are cesspits for sewage water and wastewater pits for wastewater in the basement, the sewage and wastewater is sucked up and drained to the outdoor drainage networks by submerged sewage pumps. Operation of the pumps is controlled by the magnetic floating ball controllers. Wastewater pits are provided for the underground garage, wastewater is sucked up and drained to outdoor oil separation tank by submerged sewage pumps, after treated, wastewater is drained to the outdoors rainwater networks. 在柴油发电机房,变配电房和通讯设备机房设低压二氧化碳气体灭火系统. Low pressure CO2 extinguisher systems are provided in diesel generator rooms, transformer substations and telecommunication equipment rooms. 在本建筑内按"建筑灭火器配置设计规范"在每个消火栓箱下设手提式灭火器箱,箱内设有必要数量的磷酸铵盐手提式灭火器. According to the Code for Design of Extinguisher Disposition in Buildings, portable fire extinguisher box, in which there are necessary number of portable ammonium phosphate powder extinguishers, will be installed under every hydrant box. 在每个消防电梯井底旁设有消防排水坑,废水经潜污泵提升排至室外. Fire water drain pit is provided at side of bottom of each fire elevator well, waste water will be sucked up and drained out by the pumps. 雨水系统 雨水排水屋顶采用压力流排水. 雨水设计重现期按P=10年计算,降雨历时为5分钟,暴雨强度公式按Q=(1+)/(t+)计算. 沿柱在屋面设置雨水沟.雨水通过雨水沟收集,然后进入雨水头和下排管,然后到室外雨水观察井. 10. Rainwater system Pressurized drainage system is adopted for roof rainwater drainage system. Here, return period P=10 years, rainfall duration is 5 minutes, stormwater amount is calculated by the following formula: Q=(1+)/(t+) Rainwater gutters are provided on roof along columns, skylight. Rainwater is collected in the gutter, then to rainwater heads and downpipes, and to the outdoors rainwater inspection wells. 11.管材 - 生活给水管,冷却塔补水管采用铜管,氩弧焊接. - 直饮水管采用不锈管. - 消火栓管,冷却循环管,水幕管,水泵吸水管采用焊接钢管,焊接. - 自动喷洒水管,雨淋水管采用热镀锌钢管,丝扣连接或卡压连接. -二氧化碳管采用无缝钢管焊接. - 地下车库泡沫喷淋水管采用不锈钢管,卡压连接. Pipe material Copper pipes connected by argon arc welding are adopted for the sanitary water pipes, make-up water pipes for cooling towers. Stainless stell pipes are adopted for portable water pipes. Welded steel pipes connected by welding are selected for hydrant pipes, cooling circulating pipes, drencher pipes, pump suction pipes. Hot-galvanized steel pipes connected by threads or compression-seizing are selected for sprinkler and deluge sprinler pipes. Seamless steel pipes connected by welding are selected for CO2 pipes. Stainless steel pipes connected by pressed clamp is selected for the pipes of foam sprinklers in the underground garage. 当雨水两超出雨水沟设计量时,雨水可沿屋檐自由排放.雨水被收集,然后排入市政集水池. When the amount of rainwater is more than the design value of the gutters, water is discharged naturally along the eaves. Rainwater is collected, and then drained to the municipal catch basins. 围绕体育馆的循环池将用于喷洒运动场和作为室外绿化带的储水池. 此池将作为一个循环过滤设施,可容水约 m . 喷洒压力设备和其它必须的过滤设备安装在供应楼里. The circular senic pool surround stadium will be used for spraying sportsfield and as reservoir for outdoor greening. The pool will be used as a circular filtering facility and will be adopted with a water volume of about m . The spray water pressurizing equipment as well as further necessary filtering equipment will be adopted in the supply building. 制冷 Cooling 冷源: 空调冷负荷(估算): 本工程建筑面积共平方米,包括观众区,休息室,更衣室,小会议室,餐厅,办公室和其它附属房.空调设计日峰值冷负荷为,设计日总冷负荷为3 kW. Refrigerating source Cooling load of air conditioning system Total floor area for this building is 50,000sqm, which includes spectator areas, lounges, Clothing and changing rooms small meeting rooms, restaurant, office and other auxiliary rooms. Designed dayly peak cooling load is 2,4MW, designed total dayly cooling load is 3kW. 每台1200kW制冷机配一台 流量为206m3/h离心泵.各配一台备用泵 一次泵采用压差旁路控制. 通过埋地敷管,向游泳体操馆供应冷冻水. A centrifugal pump with a flow rate of 103m3/h is provided for each 1200kW chiller. One operation pump with a standby corresponds to one chiller. Pressure difference branch control is adopted for primary pump Via earth laid pipes from supply building to gymnasium chilled water supply will be deliverded. 冷源的选择: 根据建筑的实际情况,3台制冷机将安装在供应楼内的冷冻机房.设计容量为4800kW. 为了实现能量的效率化使用,设计方案为,1台制冷机的出力为总设计容量的50%.而另2 台.每台出力为总设计容量的25%. 冷冻水系统的主要设备包括3台电动制冷机,一级冷冻泵,二级冷冻泵,自动控制阀等等.冷冻水的供/回水温度为-7/ 12°C. Selection of refrigerating source According to the real condition of the building, 3 chillers are located in the refrigerating plant rooms in the supply building, designed capacity is 2400kW. For actuing in an energy efficient way one chiller about 50% of total capacity ( kW) and two chillers with 25% of total (600 kW each)capacity each are adopted. Main equipment of chilled water system includes 3 electrical chiller, primary cool water pump, secondary chilled water pump and automatic controlled valve, etc. supply/return temperature of the chiller is-7/ 12°C. 二次泵系统:根据使用功能,各制冷机房又分成不同的循环支路. 二次泵采用变频调速控制.根据负荷侧供回水管的压差,控制水泵的转速. 二次泵循环支路的管道采用异程式. Secondary pump system: Each refrigerating plant room is subdivided into different circulation branch loops according to use functions. Variable-frequency speed-regulating control is adopted for secondary pumps. The rotating speed of a water pump is controlled according to the pressure difference between water supply and return pipes. Direct return system is adopted for the pipes of circulating branch of secondary pumps 空调冷冻水系统 由于本工程占地面积大,功能复杂,有连续使用,也有间歇使用,为了达到运行灵活,节能的目的,空调冷冻水系统采用两管制二次泵系统. Chilled water system Due to the large occupied area of this project, the complicated functions and the combination of continuous utilization and intermittent utilization, in order to accomplish the purpose of flexible operation and energy saving, the chilled water system is of two-pipe secondary pump system. 管材: 水管采用焊接钢管及无缝钢管. 本工程的风管除土建风道外,均采用镀锌铁皮咬口制作.每节风管之间用法兰连接. Pipe and duct materials The water pipes adopt welded steel pipes and seamless steel pipes. Air ducts for this project are made of galvanized sheet steel by seaming except ducts by civil construction. Air ducts are connected together by flanges. 一次泵系统: 供应楼冷冻机房 2400kW制冷机配一台离心泵, 流量为412m3/h.配一台备用泵. Primary pump system: Chiller room supply building A centrifugal pump with a flow rate of 412m3/h is provided for 1200kW chiller. One operation pump with a standby corresponds to one chiller. 保温材料: 空调供,回水管,冷凝水管采用酚醛管壳保温. 空调送,回风管以及处理后的新风管采用外贴铝箔的离心玻璃棉板保温. - 管道穿防火墙的空隙处采用岩棉材料等非燃材料填充. Thermal materials phenolic pipes are adopted for thermal insulation of water supply and return pipes for air conditioning, as well as air-conditioning condensate pipes. Aluminum foil faced glass fiber boards are adopted for thermal insulation of air-conditioning air supply and return ducts as well as fresh air ducts after chillers. Non-flammable material will be selected to fill the interspace in the fire protection wall where the ducts go through. 消声与隔振: 冷水机组,水泵等设备采用减振台座,弹簧减振器或橡胶减振垫减振降噪. 在空调机组,新风机组,通风机的进出口采用涂胶帆布软管连接. - 水泵进出水管上采用可曲挠橡胶接头,使设备振动与配管隔离. Noise reduction and vibration isolation Shock absorption bases, spring shock absorbers on rubber shock absorption pads are adopted for equipment, such as water chiller units, pumps, etc to reduce vibration and lower noise. Flexible rubber-coated canvas hoses are adopted far connections of inlets and outlets of air-conditioning units, fresh air handling units and ventilators. Flexible rubber couplings are adopted for the water intake and delivery pipes of the pumps to isolate equipment vibration from their pipes. 空调和通风系统 Air Conditioning and Ventilation Systems 方案设计范围 Scope of schematic design 空调设计 Air Conditioning Design 在体育馆内,一些区域设置空调系统.这些区域划分为: 西侧地下二层的贵宾休息室 东侧地下二层酒店门廊 地下一层的输送区,技术机房,运动员更衣间,医务服务,热身区,裁判区,健身中心,酒店大堂,会议室,厨房,特许区和贵宾大堂混合区. 首层的酒店大堂,酒店区,贵宾门廊,急救 In the stadium, in some ranges air conditioning systems are used. These ranges subdivide themselves as follows: VIP – Lobby in West of levelel -2 Hotel lobby in the east of level –2 Delivary Circle, technical Plantrooms, Changingrooms for the athletes, Medical Service and warm up area, Judges Area, Fitness Center, Hotel Lobby, Conferenz, Kitchen and Concession, Vip lobby- Mixed Zone in level -1 Hotel lobby, Hotel area, Vip lobby, Vip Area, First aid in 0

随着我国现代建筑技术的不断发展,人们对于建筑给排水工程方面也提出了越来越高的的要求。下文是我为大家整理的关于建筑给排水工程论文的范文,欢迎大家阅读参考!

浅谈高层建筑给排水工程设计

摘要:对高层建筑给水系统设计,排水系统设计、室内消防和热水系统设计进行了详细介绍,总结出目前高层建筑给排水存在的问题,并探讨了给排水节水措施,以确保水资源的合理利用。

关键词:建筑给排水;高层建筑;设计;节水措施

1、高层建筑给排水工程设计方法

高层建筑给水排水工程与一般多层建筑和低层建筑给水排水工程相比,基本的理论和计算方法是一致的,但因高层建筑层数多,高度大,结构复杂。近年来建筑给水工程设计方法得到改进。

例:给一个高层建筑为15层的楼房设计给排水:

住宅楼为框架结构,共15层,层高,室外给水管网位于建筑物的北侧,距离外墙为10m,接管点埋深,管径400mm,管材为球墨给水铸铁管,常年提供的水头;室内粪便污水需要经过化粪池处理方可排入市政管网,室外排水管网位于建筑物的南侧,埋深2m,管径600mm,管材为聚乙烯双壁波纹排水塑料管。

设计参数

生活用水定额:qd=150L/(人.d);最大小时生活用水量:Qh=;最高日用水量:Qd=;小时变化系数:kh=;每户人口:m=人;共90户;室内消防用水量:10L/s;消防水箱水量为火灾前10min的水量6m?;贮水池内的消防水量:按火灾延续2h的水量计;雨水重现期:2年。

设计内容

给水系统设计

管道采用钢塑复合管(内衬塑外镀锌)螺纹连接,进行干管安装、立管安装、支管安装,管道安装完毕需进行水压试验,压力设在,并对安装好的管道做好防腐和保温工作,冲洗管道对其进行管道通水试验。

根据《建筑给排水设计手册》上卫生器具的最大静水压力不得超过,因此高层建筑给水系统必须分区。设计任务书给定了市政给水管网提供常年的水压为。根据给水最小所需压力估算方法:第1层,第2层,2层以上增加1层,压力需增加。得的压力能直接供到第6层还多。所以1层~6层为一个区,上面7层~15层为一个区,总共就两个区。1层~6层用市政管网直接供水,其中底层和2层~6层单独设立管。

考虑到此设计对象是15层的高层建筑。市政管网提供的压力不能全部直接供水,所以必须对生活用水进行提升或加压。高层建筑设计一般都使用高位水箱供水,供水压力比较稳定,此设计也使用高位水箱;又因此设计面向高层民用住宅楼,通过查看平面图纸,根据建筑物的布置情况和楼层的承载力情况及水箱本身占用大量的建筑面积,即在楼层中间没有建筑面积可允许安置水箱,串联供水不可实现,因此高区的供水应在地面用泵抽升到高区水箱。

方案(一)与方案(二)相比管材使用量、工程投资相对较少,但它对减压阀的质量要求相对较高,一旦减压阀受损或使用性能降低,低区的静水压力会迅速增加,影响卫生器具的使用。方案(二)采用低区市政管网直接供水,消除了通过依赖减压阀降低静水压力来减少低区供水的现象。基于工程质量和供水水质及水压的可靠性,最终选择方案(二)

排水系统设计

室内排水系统为污水、废水合流系统,地上部分直接排出室外,地下部分分段设置集水坑把地下室污水、废水汇集于坑内,利用潜水泵由集水坑自动控制将其提升至室外。为了保护存水弯水封性能,保持排水系统内的空气压力与大气压取得平衡,使排水管内排水畅通,向排水管内通入新鲜的空气,保持管内的换气,防范因室外管道系统积聚起来的有害气体而伤害到养护人员、引发火灾和腐蚀管道等隐患,还应减少排水系统的噪声,在排水系统中设置通气管。

室内消防工程

室内消火栓给水系统有:分区、不分区两种方式。消火栓的静水压力超过时就需要分区供水,而本设计是15层的小高层,高度不超过50m,静水压力小于,可以不分区。同时本设计的建筑是15层小高层民用住宅楼,造成火灾的隐患少,人员疏散也快,扑救难度不大,高压消防给水无须设置常年的。设置专用的消防泵,从贮水池内抽取消防水,可用生活给水箱在火灾发生初期10min提前给水,并设置止回阀,既消除了消防水箱对楼层负荷,又可减少工程投资。此设计是15层小高层,层高,总楼高不超过45m,根据建筑给排水设计手册!规定消防栓的最大静水压力不超过,此设计无须分区消防供水,可利用消防泵直接供水满足条件。

室内热水工程

应根据建筑物的用途、热源的供给情况、热水用量和卫生器具的布置情况进行技术和经济比较来确定何种热水供应方式。热水供水方式有如下几类。按供应范围不同有:集中供热、局部供热、区域供热。

2、目前建筑给排水存在的问题

控制超压出流产生的水量浪费

生活给水系统按规定竖向分区后仍然存在着部分卫生器具配水点水压偏大的问题,而这是常常被忽视的。卫生器具的额定流量少于单位时间内的出水量,影响给水系统正常分配水的流量。如不采取减压节流措施,将造成水资源浪费、水压过高、漏水量增加等弊病,同时易产生水击、噪声和振动,致使管件损坏和破裂。这些水量的浪费不容忽视。

管道和阀门的损坏

我们可看到的路边给水管道在管子接缝处及法兰、阀门连接处向外冒水,而我们看不见的地下更不知有多少漏水处。管道受损及腐蚀,阀门不严等问题导致大量水流失。

热水系统浪费水量巨大

建筑热水供应已成为建筑给水的重要部分,由于设计不当,其浪费已非常严重,造成一定损失。所以给水系统供水应保证冷热水压力均衡,采用循环系统以确保每户开龙头就有热水,降低水量浪费。

3、我国建筑给排水节水措施

提高用水效率

1)严格执行生活用水量定额标准,饮用水、生活用水、景观用水、绿化用水按各个水质要求分别供给。

2)采用节水系统,如节水的卫生器具,利用限制卫生器具的流出水头、红外线感应龙头和便器等。

3)选择一个可再生能源,如风能、太阳能、水能、海洋能、地热能、生物能等非化石能源用于建筑的热水供应。对于不同的场合采用不同的热源形式。

雨水的利用

利用雨水收集系统再循环得到符合标准的水质进行绿化浇灌,处理后的雨水还可用于冲洗厕所,这不仅可减少用水量还可减轻污染。提高地基的保水能力,合理规划雨水流经途径,引入雨水沉淀池再利用。

污水排放和二次利用

建筑中水系统是典型的资源可持续利用装置,将建筑物产生的污水、废水加以收集并对其处理,在节省资源和保护环境的基础上对生活污水和废水的重复利用。

节水指标

节水指标有三类:

1)雨洪水利用率:常年降雨量除以使用或收集量;

2)水使用率:正常使用量除以使用量;

3)循环量:一次性用量乘以循环次数。

4、结语

在给排水设计时,我们应正确合理的选择系统和方案,以达到节水节能的目的,确保水资源的合理利用。

参考文献:

[1]孙志魁.我国绿色建筑给排水节能新技术的应用新探.中国新技术新产品,2012(1):45.

[2]杨天峰,张旺.低碳经济下建筑给排水的节能问题研究.科技创业月刊,2010,23(9):161-162.

[3]赵培林.浅议绿色建筑住宅的节水设计.机电产品开发与创新,2009,22(3):40-41.

[4]李倩.绿色建筑给排水设计的节水途径探析.企业导报,2012(1):273.

浅析建筑工程给排水施工技术

摘要:本文作者结合实际工作经验,对建筑工程的给排水施工技术进行了分析,提出了自己的见解。

关键词:建筑工程;给排水;施工技术

随着我国现代建筑技术的不断发展,人们对于建筑给排水工程方面也提出了越来越高的的要求。在设计和施工时要不断积累经验,深入分析各种常见问题,促进给排水施工技术的发展。

1 建筑给水方面的管道施工

给水管道材料的种类和选用

现在在新型建筑中用的较多的给水管材主要包括:聚丙烯类、聚乙烯类、聚丁烯类、工程塑料类,以及还有一些复合管类,例如:钢塑管、铝塑管、铜塑复合管等。虽然可供选择的材料有许多种,但在每一个具体施工工程中也必须根据实际情况进行选择。而且在管材的选用上还受到许多因素的影响,必须对国家政策、施工标准、地区特点、工程性质以及施工标准等因素进行综合考虑,选择最优管材。其中还要特别注意的是,管道的使用位置以及其使用方法是在管材选用时需要着重考虑的,还有就是管件与连接也是选取管材时容易忽视的一个关键的问题。

给水管道的施工

在对给水管做热熔连接时,必须要掌握好加热的时间和连接将要插入的深度。如果加热时间过长就使水管融化,如果加热时间过短也不能更好连接;如果插的过深,就会造成管道断面减少;如果插的过浅也会使降低接口处强度。所以,加热时的温度、加热时间和接缝压力是影响热熔连接质量的三个关键因素。

2 建筑排水管道常见问题的原因分析

排水管道方面经常出现的问题是漏水、堵塞问题。出现这些问题的原因也比较多,第一,就是施工中出现的问题,大多是施工单位没有选择合格的管材,为了一时经济利益以次充好,或者是在安装前没有进行漏水实验,也或是一些不合格的材料运用到工程中导致漏水现象的发生;比如说管道穿墙(楼板)设置套管的缺陷与不足较为普遍。有的虽然加了套管,穿越楼板与楼板面齐平或嵌入楼板有的穿越墙面,比饰面多出20-50mm,有的没有设套管或预埋套管偏位,于脆用水泥圈(楼面)塑料圈(墙面)护(粘)住,掩人耳目,有的套管比管道只大一个规格,有的大三至五个规格,套管与管道间隙有的用泡沫、油麻堵塞等等套管的设置应按(GB50242-2002)规范第规定.“安装在楼板内的套管,其顶部应高出装饰地面20mm,安装在卫生间及厨房内的套管,其顶部应高出装饰地面50mm,底部应与楼板底面相平,安装在墙壁内的套管其两端与饰面相平。穿过楼板的套管与管道之间缝隙应用阻燃密实材料和防水油膏填实。端面光滑。穿墙套管与管道之间缝隙宜用阻燃密实材料填实,且端面应光滑。管道的接口不得设在套管内”。第二,就是设计方面出现了问题,导致管道安装好以后容易堵塞;第三,就是住户使用时出现了问题。

3 建筑给排水施工的特点

管道安装具有的特点

在这几年里,给水管道的材料大多使用的是PP-R管和UPVC管。因为这两种管道具有轻便、耐高压、抗腐蚀、质量安全、使用卫生、通水阻力小、使用寿命较长的特性,所以安装中最明显的特点就是便于安装。对于PP-R管的安装来说,连接前要清除管道上附着的灰尘后,在按照严格的施工流程来进行安装,但是其中需要注意的是在在对管道进行热熔是一定不能旋转,以免加热过度,而且在管道连通后还要采取一定措施对其进行冷却。对于UPVC管的安装来说,安装时一定要使用排水胶粘结。在涂完胶以后还要注意的就是胶干时间,具体的时间应依据当地气候和温度的变化来进行调节,还要注意不能沾水。如果是在环境温差较大的地方安装,必须使用管道伸缩节。

给排水管道的试压

当所有管道安装完成之后,还要对所有部位进行全面的检测,主要包括检测已安装的管道和阀门等设备是否符合设计和技术要求规定,如果有问题应立即拆除予以更换或是维修。检测的具体方法是用临时的短管来替代安装的管道,把所有的开口处封闭,从管道最低处开始灌水,在最高处进行放气。如果出现异样,要及时停止检测,并立即排水。在试压完成后,还对所有管道要进行吹洗。

4 提高建筑的给排水施工技术的具体措施

随着建筑技术的发展,生产工艺的不断改进和提高,对给排水工程的设计、施工、维修和运行管理的要求也就越来越高。要想使管网达到优质、高效、低能耗运行的目的,除要有合理的设计方案外,给排水系统安装质量的优劣将会对日后的使用产生极大的影响。

管道施工的措施

对于管道的施工来说主要是注意加热时间、加热温度、接缝压力这三个方面的问题,施工中运用最多的是钢塑复合管,在对其施工中应采用螺纹连接的方法,插入管道的长度应严格按照标准旋转深度进行控制;在对管端和管螺纹进行加工后,还要进行密封处理,这时需要使用聚四氟乙烯生料带来进行缠绕螺纹;施工中需要选用厌氧密封胶密封过的管道接头,必须在养护24h之后再进行试压。施工中要用专门的施工机具,不能随便更该。

W型铸铁管的施工方法

有关W型铸铁管的具体施工措施,第一步就是下料,在切割管材时要选用专门的切割工具,主要是保证管口的平直。第二步是连接,进行连接时先要松开卡箍,再取出内衬中的橡胶圈,把箍套和橡胶圈放在入管口的一侧,使管口对齐后,随后把橡胶圈放在接口上,最后锁紧了箍套紧固了螺丝就算完成了管道连接。第三步低支架的设置,对于一般的管材安装来说,如果每隔3m设置一个支架其实是可以的,但是对于W型无承口机制排水铸铁管接口来说就不行了,因为其属于柔性接口,当支架放在管道中间时,理论上可以将管道保持平衡,可是在实际工作中,找到重心点是很难的,所以经常无法保证管道接口的平滑,如果采用每隔设置一个支架的方法来进行布置,这样就可以很好地解决管道外观和管道坡度的问题。

建筑给排水施工的监管

给排水管道的设计与施工是一项很复杂的措施,其中关于管道的铺设和管道的安装都容易出现问题,所以有关管道施工的监督也是一项非常重要的方面。因为管道施工工期较长设计建筑工程的的许多阶段,所以监管也可以分为多个阶段来进行。

首先,在工程施工前期阶段的监管,在施工前就应该仔细阅读施工图纸,充分了解设计者的设计意图和目的,这样才能保证施工过程中不偏离设计图纸的要求,也不能在施工中随意变更设计方案。

其次,是在基础主体结构施工阶段的监管,在基础主体施工中,要注意排水系统的排水管和给水管的引入管在穿越建筑物或地下构筑物外墙处时,是否按设计要求预留好了足够的孔洞以及设置好的套管。

再次,就是装修阶段的监管,在装修施工阶段主要是对给排水管道系统安装阶段,主要是注意装修工程不能破坏原有的管道路线的设置或是预留管道的破坏,必须在明确所有管道布置之后再结合装修方案进行施工。

5 结束语

随着我国建筑技术的不断发展,对给排水工程的设计、施工和运行管理等方面的要求也越来越高。优质的安装施工质量和科学的管理是保障管网系统高效安全运行的必要条件。为了满足给排水建筑施工技术要求,提高施工质量,需要施工人员不断学习,提高自身的技术素质,只有这样,才能保证安装工程的质量,立足于建筑安装工程的基本建设。

参考文献:

[1] 王胜飞;民用建筑给排水工程施工质量常见问题及预防措施[J].中小企业管理与科技(下旬刊),2010,(08).

[2] 金生;建筑工程给排水施工常见问题解决措施探讨[J].现代商贸工业,2011,(09).

[3] 刘康;建筑工程给排水施工常见问题及解决措施研究[J].科技致富向导,2011,(01).

[4] 何新辉,魏晓斌.高层建筑给排水设计分析研究[J].中国房地产业,2011,(04).

[5] 李霞,高层建筑给水排水工程课程教学实践与探讨[J].山西建筑,2011,(01).

关于建筑给水排水设计论文

随着我国现代建筑技术的不断发展,人们对于建筑给排水工程方面也提出了越来越高的的要求。下文是我为大家整理的关于建筑给排水工程论文的范文,欢迎大家阅读参考!

浅谈高层建筑给排水工程设计

摘要:对高层建筑给水系统设计,排水系统设计、室内消防和热水系统设计进行了详细介绍,总结出目前高层建筑给排水存在的问题,并探讨了给排水节水措施,以确保水资源的合理利用。

关键词:建筑给排水;高层建筑;设计;节水措施

1、高层建筑给排水工程设计方法

高层建筑给水排水工程与一般多层建筑和低层建筑给水排水工程相比,基本的理论和计算方法是一致的,但因高层建筑层数多,高度大,结构复杂。近年来建筑给水工程设计方法得到改进。

例:给一个高层建筑为15层的楼房设计给排水:

住宅楼为框架结构,共15层,层高,室外给水管网位于建筑物的北侧,距离外墙为10m,接管点埋深,管径400mm,管材为球墨给水铸铁管,常年提供的水头;室内粪便污水需要经过化粪池处理方可排入市政管网,室外排水管网位于建筑物的南侧,埋深2m,管径600mm,管材为聚乙烯双壁波纹排水塑料管。

设计参数

生活用水定额:qd=150L/(人.d);最大小时生活用水量:Qh=;最高日用水量:Qd=;小时变化系数:kh=;每户人口:m=人;共90户;室内消防用水量:10L/s;消防水箱水量为火灾前10min的水量6m?;贮水池内的消防水量:按火灾延续2h的水量计;雨水重现期:2年。

设计内容

给水系统设计

管道采用钢塑复合管(内衬塑外镀锌)螺纹连接,进行干管安装、立管安装、支管安装,管道安装完毕需进行水压试验,压力设在,并对安装好的管道做好防腐和保温工作,冲洗管道对其进行管道通水试验。

根据《建筑给排水设计手册》上卫生器具的最大静水压力不得超过,因此高层建筑给水系统必须分区。设计任务书给定了市政给水管网提供常年的水压为。根据给水最小所需压力估算方法:第1层,第2层,2层以上增加1层,压力需增加。得的压力能直接供到第6层还多。所以1层~6层为一个区,上面7层~15层为一个区,总共就两个区。1层~6层用市政管网直接供水,其中底层和2层~6层单独设立管。

考虑到此设计对象是15层的高层建筑。市政管网提供的压力不能全部直接供水,所以必须对生活用水进行提升或加压。高层建筑设计一般都使用高位水箱供水,供水压力比较稳定,此设计也使用高位水箱;又因此设计面向高层民用住宅楼,通过查看平面图纸,根据建筑物的布置情况和楼层的承载力情况及水箱本身占用大量的建筑面积,即在楼层中间没有建筑面积可允许安置水箱,串联供水不可实现,因此高区的供水应在地面用泵抽升到高区水箱。

方案(一)与方案(二)相比管材使用量、工程投资相对较少,但它对减压阀的质量要求相对较高,一旦减压阀受损或使用性能降低,低区的静水压力会迅速增加,影响卫生器具的使用。方案(二)采用低区市政管网直接供水,消除了通过依赖减压阀降低静水压力来减少低区供水的现象。基于工程质量和供水水质及水压的可靠性,最终选择方案(二)

排水系统设计

室内排水系统为污水、废水合流系统,地上部分直接排出室外,地下部分分段设置集水坑把地下室污水、废水汇集于坑内,利用潜水泵由集水坑自动控制将其提升至室外。为了保护存水弯水封性能,保持排水系统内的空气压力与大气压取得平衡,使排水管内排水畅通,向排水管内通入新鲜的空气,保持管内的换气,防范因室外管道系统积聚起来的有害气体而伤害到养护人员、引发火灾和腐蚀管道等隐患,还应减少排水系统的噪声,在排水系统中设置通气管。

室内消防工程

室内消火栓给水系统有:分区、不分区两种方式。消火栓的静水压力超过时就需要分区供水,而本设计是15层的小高层,高度不超过50m,静水压力小于,可以不分区。同时本设计的建筑是15层小高层民用住宅楼,造成火灾的隐患少,人员疏散也快,扑救难度不大,高压消防给水无须设置常年的。设置专用的消防泵,从贮水池内抽取消防水,可用生活给水箱在火灾发生初期10min提前给水,并设置止回阀,既消除了消防水箱对楼层负荷,又可减少工程投资。此设计是15层小高层,层高,总楼高不超过45m,根据建筑给排水设计手册!规定消防栓的最大静水压力不超过,此设计无须分区消防供水,可利用消防泵直接供水满足条件。

室内热水工程

应根据建筑物的用途、热源的供给情况、热水用量和卫生器具的布置情况进行技术和经济比较来确定何种热水供应方式。热水供水方式有如下几类。按供应范围不同有:集中供热、局部供热、区域供热。

2、目前建筑给排水存在的问题

控制超压出流产生的水量浪费

生活给水系统按规定竖向分区后仍然存在着部分卫生器具配水点水压偏大的问题,而这是常常被忽视的。卫生器具的额定流量少于单位时间内的出水量,影响给水系统正常分配水的流量。如不采取减压节流措施,将造成水资源浪费、水压过高、漏水量增加等弊病,同时易产生水击、噪声和振动,致使管件损坏和破裂。这些水量的浪费不容忽视。

管道和阀门的损坏

我们可看到的路边给水管道在管子接缝处及法兰、阀门连接处向外冒水,而我们看不见的地下更不知有多少漏水处。管道受损及腐蚀,阀门不严等问题导致大量水流失。

热水系统浪费水量巨大

建筑热水供应已成为建筑给水的重要部分,由于设计不当,其浪费已非常严重,造成一定损失。所以给水系统供水应保证冷热水压力均衡,采用循环系统以确保每户开龙头就有热水,降低水量浪费。

3、我国建筑给排水节水措施

提高用水效率

1)严格执行生活用水量定额标准,饮用水、生活用水、景观用水、绿化用水按各个水质要求分别供给。

2)采用节水系统,如节水的卫生器具,利用限制卫生器具的流出水头、红外线感应龙头和便器等。

3)选择一个可再生能源,如风能、太阳能、水能、海洋能、地热能、生物能等非化石能源用于建筑的热水供应。对于不同的场合采用不同的热源形式。

雨水的利用

利用雨水收集系统再循环得到符合标准的水质进行绿化浇灌,处理后的雨水还可用于冲洗厕所,这不仅可减少用水量还可减轻污染。提高地基的保水能力,合理规划雨水流经途径,引入雨水沉淀池再利用。

污水排放和二次利用

建筑中水系统是典型的资源可持续利用装置,将建筑物产生的污水、废水加以收集并对其处理,在节省资源和保护环境的基础上对生活污水和废水的重复利用。

节水指标

节水指标有三类:

1)雨洪水利用率:常年降雨量除以使用或收集量;

2)水使用率:正常使用量除以使用量;

3)循环量:一次性用量乘以循环次数。

4、结语

在给排水设计时,我们应正确合理的选择系统和方案,以达到节水节能的目的,确保水资源的合理利用。

参考文献:

[1]孙志魁.我国绿色建筑给排水节能新技术的应用新探.中国新技术新产品,2012(1):45.

[2]杨天峰,张旺.低碳经济下建筑给排水的节能问题研究.科技创业月刊,2010,23(9):161-162.

[3]赵培林.浅议绿色建筑住宅的节水设计.机电产品开发与创新,2009,22(3):40-41.

[4]李倩.绿色建筑给排水设计的节水途径探析.企业导报,2012(1):273.

浅析建筑工程给排水施工技术

摘要:本文作者结合实际工作经验,对建筑工程的给排水施工技术进行了分析,提出了自己的见解。

关键词:建筑工程;给排水;施工技术

随着我国现代建筑技术的不断发展,人们对于建筑给排水工程方面也提出了越来越高的的要求。在设计和施工时要不断积累经验,深入分析各种常见问题,促进给排水施工技术的发展。

1 建筑给水方面的管道施工

给水管道材料的种类和选用

现在在新型建筑中用的较多的给水管材主要包括:聚丙烯类、聚乙烯类、聚丁烯类、工程塑料类,以及还有一些复合管类,例如:钢塑管、铝塑管、铜塑复合管等。虽然可供选择的材料有许多种,但在每一个具体施工工程中也必须根据实际情况进行选择。而且在管材的选用上还受到许多因素的影响,必须对国家政策、施工标准、地区特点、工程性质以及施工标准等因素进行综合考虑,选择最优管材。其中还要特别注意的是,管道的使用位置以及其使用方法是在管材选用时需要着重考虑的,还有就是管件与连接也是选取管材时容易忽视的一个关键的问题。

给水管道的施工

在对给水管做热熔连接时,必须要掌握好加热的时间和连接将要插入的深度。如果加热时间过长就使水管融化,如果加热时间过短也不能更好连接;如果插的过深,就会造成管道断面减少;如果插的过浅也会使降低接口处强度。所以,加热时的温度、加热时间和接缝压力是影响热熔连接质量的三个关键因素。

2 建筑排水管道常见问题的原因分析

排水管道方面经常出现的问题是漏水、堵塞问题。出现这些问题的原因也比较多,第一,就是施工中出现的问题,大多是施工单位没有选择合格的管材,为了一时经济利益以次充好,或者是在安装前没有进行漏水实验,也或是一些不合格的材料运用到工程中导致漏水现象的发生;比如说管道穿墙(楼板)设置套管的缺陷与不足较为普遍。有的虽然加了套管,穿越楼板与楼板面齐平或嵌入楼板有的穿越墙面,比饰面多出20-50mm,有的没有设套管或预埋套管偏位,于脆用水泥圈(楼面)塑料圈(墙面)护(粘)住,掩人耳目,有的套管比管道只大一个规格,有的大三至五个规格,套管与管道间隙有的用泡沫、油麻堵塞等等套管的设置应按(GB50242-2002)规范第规定.“安装在楼板内的套管,其顶部应高出装饰地面20mm,安装在卫生间及厨房内的套管,其顶部应高出装饰地面50mm,底部应与楼板底面相平,安装在墙壁内的套管其两端与饰面相平。穿过楼板的套管与管道之间缝隙应用阻燃密实材料和防水油膏填实。端面光滑。穿墙套管与管道之间缝隙宜用阻燃密实材料填实,且端面应光滑。管道的接口不得设在套管内”。第二,就是设计方面出现了问题,导致管道安装好以后容易堵塞;第三,就是住户使用时出现了问题。

3 建筑给排水施工的特点

管道安装具有的特点

在这几年里,给水管道的材料大多使用的是PP-R管和UPVC管。因为这两种管道具有轻便、耐高压、抗腐蚀、质量安全、使用卫生、通水阻力小、使用寿命较长的特性,所以安装中最明显的特点就是便于安装。对于PP-R管的安装来说,连接前要清除管道上附着的灰尘后,在按照严格的施工流程来进行安装,但是其中需要注意的是在在对管道进行热熔是一定不能旋转,以免加热过度,而且在管道连通后还要采取一定措施对其进行冷却。对于UPVC管的安装来说,安装时一定要使用排水胶粘结。在涂完胶以后还要注意的就是胶干时间,具体的时间应依据当地气候和温度的变化来进行调节,还要注意不能沾水。如果是在环境温差较大的地方安装,必须使用管道伸缩节。

给排水管道的试压

当所有管道安装完成之后,还要对所有部位进行全面的检测,主要包括检测已安装的管道和阀门等设备是否符合设计和技术要求规定,如果有问题应立即拆除予以更换或是维修。检测的具体方法是用临时的短管来替代安装的管道,把所有的开口处封闭,从管道最低处开始灌水,在最高处进行放气。如果出现异样,要及时停止检测,并立即排水。在试压完成后,还对所有管道要进行吹洗。

4 提高建筑的给排水施工技术的具体措施

随着建筑技术的发展,生产工艺的不断改进和提高,对给排水工程的设计、施工、维修和运行管理的要求也就越来越高。要想使管网达到优质、高效、低能耗运行的目的,除要有合理的设计方案外,给排水系统安装质量的优劣将会对日后的使用产生极大的影响。

管道施工的措施

对于管道的施工来说主要是注意加热时间、加热温度、接缝压力这三个方面的问题,施工中运用最多的是钢塑复合管,在对其施工中应采用螺纹连接的方法,插入管道的长度应严格按照标准旋转深度进行控制;在对管端和管螺纹进行加工后,还要进行密封处理,这时需要使用聚四氟乙烯生料带来进行缠绕螺纹;施工中需要选用厌氧密封胶密封过的管道接头,必须在养护24h之后再进行试压。施工中要用专门的施工机具,不能随便更该。

W型铸铁管的施工方法

有关W型铸铁管的具体施工措施,第一步就是下料,在切割管材时要选用专门的切割工具,主要是保证管口的平直。第二步是连接,进行连接时先要松开卡箍,再取出内衬中的橡胶圈,把箍套和橡胶圈放在入管口的一侧,使管口对齐后,随后把橡胶圈放在接口上,最后锁紧了箍套紧固了螺丝就算完成了管道连接。第三步低支架的设置,对于一般的管材安装来说,如果每隔3m设置一个支架其实是可以的,但是对于W型无承口机制排水铸铁管接口来说就不行了,因为其属于柔性接口,当支架放在管道中间时,理论上可以将管道保持平衡,可是在实际工作中,找到重心点是很难的,所以经常无法保证管道接口的平滑,如果采用每隔设置一个支架的方法来进行布置,这样就可以很好地解决管道外观和管道坡度的问题。

建筑给排水施工的监管

给排水管道的设计与施工是一项很复杂的措施,其中关于管道的铺设和管道的安装都容易出现问题,所以有关管道施工的监督也是一项非常重要的方面。因为管道施工工期较长设计建筑工程的的许多阶段,所以监管也可以分为多个阶段来进行。

首先,在工程施工前期阶段的监管,在施工前就应该仔细阅读施工图纸,充分了解设计者的设计意图和目的,这样才能保证施工过程中不偏离设计图纸的要求,也不能在施工中随意变更设计方案。

其次,是在基础主体结构施工阶段的监管,在基础主体施工中,要注意排水系统的排水管和给水管的引入管在穿越建筑物或地下构筑物外墙处时,是否按设计要求预留好了足够的孔洞以及设置好的套管。

再次,就是装修阶段的监管,在装修施工阶段主要是对给排水管道系统安装阶段,主要是注意装修工程不能破坏原有的管道路线的设置或是预留管道的破坏,必须在明确所有管道布置之后再结合装修方案进行施工。

5 结束语

随着我国建筑技术的不断发展,对给排水工程的设计、施工和运行管理等方面的要求也越来越高。优质的安装施工质量和科学的管理是保障管网系统高效安全运行的必要条件。为了满足给排水建筑施工技术要求,提高施工质量,需要施工人员不断学习,提高自身的技术素质,只有这样,才能保证安装工程的质量,立足于建筑安装工程的基本建设。

参考文献:

[1] 王胜飞;民用建筑给排水工程施工质量常见问题及预防措施[J].中小企业管理与科技(下旬刊),2010,(08).

[2] 金生;建筑工程给排水施工常见问题解决措施探讨[J].现代商贸工业,2011,(09).

[3] 刘康;建筑工程给排水施工常见问题及解决措施研究[J].科技致富向导,2011,(01).

[4] 何新辉,魏晓斌.高层建筑给排水设计分析研究[J].中国房地产业,2011,(04).

[5] 李霞,高层建筑给水排水工程课程教学实践与探讨[J].山西建筑,2011,(01).

随着城市发展规模的加大、整体水平的提升,建筑排水成为了城市建筑建设中非常重要的一项工作。下文是我为大家蒐集整理的的内容,欢迎大家阅读参考!

试谈建筑工程给排水施工装置管理策略

【摘 要】 伴随着住宅小区建设的不断增多,建筑工程中出现了很多的给排水问题,这些问题不但影响了居民的正常生活,而且严重影响了人们对企业的形象,因此,要对建筑工程给排水问题做有效的处理,防止出现各种建筑给排水隐患,从而保证了建筑工程给排水建设的质量和水平。本文结合实践经验,在分析给排水系统存在问题的基础上,提出相应的装置管理策略,针对性较强。

【关键词】 建筑工程;给排水;施工装置;管理;策略

1 引言

市政给排水作为一个重要的城市基础设施,它包括供水系统和排水系统两大部分组成的,其中供水系统是由消防给水管道、生活给水管道、生产给水管道等组成的,而排水系统是由生产生活污水排放管道、清净水下水管道以及雨水下水等管道组成的。这些复杂的管道都是敷设在地下的,并且管道的布线较长,范围较大,如果产生了安全问题,那么就会影响其他装置的正常运转,甚至会影响正常的生产生活。

2 给水系统施工管理中存在的问题及处理措施

给水试压

在生活给水管道安装结束后,施工人员就直接进行了隐蔽,因而容易造成渗漏隐患,为了防止此情况的发生,应进行给水试压。在试压的过程中,要保证所有的阀门开启,显示出所有的渗漏隐患,同时要检查压力表是否合格,对于不合格的产品,要严禁使用。可以通过转动所有支管阀门并确定是否有水声,以确保阀门处于开启状态。

分水器安装

用水多的厨房和卫生间,应根据实际情况适当采用分水器。在布管施工过程中,要采用多支路单向布管方式,将每一根配水管直通到配水点与卫生器具和水龙头等连线处,尽量减少分支管,从而减少出现漏水点的可能。

生活用水水池的溢流管

对于水池溢流管的管径小于进水管且没有安装网罩时,在这种情况下,水位控制器一旦失灵,容易造成多余的水不能从溢流管顺利排出。因此在施工中应该使溢流管的管径应按照排泄贮水池最大流量来确定,并且可比进水管稍大一些。

给水系统中的减压阀

如果在给水系统中的减压阀前后没有设定阀门,就会造成减压阀无法检修。对于减压阀前没有安装过滤器的情况,容易造成水中的杂物堵塞减压阀。因此,在给水系统中减压阀前后都应安装阀门,防止杂物堵住减压阀造成失灵的情况,保证减压阀正常工作。

水表、阀门安装

水表、阀门安装不仅要方便和美观,而且要采取一定保护措施,注意居民的安全问题。这就要求水表应安装在便于检修、不受暴晒和污染的地方,且水表和阀门要水平安装。

3 排水系统施工管理中存在的问题及处理措施

地漏施工

在地漏安装过程中,要使得室内地漏的安装和地面保持一致,太高容易使得积水容易从地漏里流出,会出现积水现象,影响使用环境;太低容易形成地坑,容易使污物堆积在地漏上,影响地面的洁净且不便行走。对于公用卫生间采用格栅型地漏,防止堵塞的发生。

坐便器排水口位置的选择

有关坐便器安装过程中,要选择合适的型号,选择合理的位置以便适应多种坐便器型号对排水口位置的要求,这就要求安装时距离墙面要适当,同时要注明洁具间距,防止出现无法安装淋浴的情况,排水口距离墙面的距离一般为 300mm,考虑装修前的墙面的距离宜为340mm。

UPVC排水管道施工

在UPVC排水管道的安装过程中,要设定套管等保护措施,防止套管不满足防水的要求,而出现渗漏隐患,根据要求,排水管道在穿越上述部位时均应加设、预埋刚性防水套管,并且当排水立管管径大于或等于110mm时,在楼板贯穿部位还应设定阻火圈。

施工人员施工存在的问题及处理措施

有的施工人员在施工过程中将室内雨水管道接入生活污水管道或天面雨水与阳台合用,可能会导致多雨季节超出生活污水管道的排水能力,使得污水外溢,影响环境卫生。《建筑给水排水设计规范》规定建筑物雨水管道应单独排出,而且天面雨水应与阳台分开,以防止雨水季节的污水外溢现象。

排水支管

在安装排水支管过程中,施工人员为迁就预留口的位置和接管尺寸,而将排水支管做成无坡度、坡度小、甚至倒坡。这就会导致卫生洁具下水口与支管连线不好,排水管道排水不畅通,严重时会造成堵塞现象,应对排水支管采取一定的措施,防止堵塞情况的发生。

4 消防给水系统施工中存在的问题及处理措施

消火栓阀存在的问题及处理措施

在安装消防栓的过程中,要在给水系统中按规定要求在需减压处安装减压孔等减压装置,如果设定中没有设定减压等装置,将会导致消火栓栓口的静水压力过大,由于栓口处长期保持高静压力,很容易造成消火栓栓阀的损坏,当发生火灾的时候,会造成使用困难。按照规定,当消火栓栓口的出水压力大于 时,应设定减压孔板等减压装置。当消火栓栓口的静水压力大于 时就应该采取分割槽给水系统。通过这些措施可以有效的减低栓口的高静压力,防止栓阀的损坏。

管网施工中存在的问题及处理措施

管网的试压分为两项,一项分为强度试验,另一项分为严密性试验。在施工的过程中,有的施工人员为了图方便,只进行强度试验,或者只做严密性试验,甚至完全不做任何试验,这会给整个消防系统的正常执行带来了严重的安全隐患,因此,在施工过程中一定要按照要求进行质量验收,并进行强度试验和严密性试验。

自动喷水灭火系统管网穿梁套管存在的问题及处理措施

自动喷水灭火系统管道的穿梁套管的预埋要比普通的排水套管预埋要求要更高一些由于每一支管的所有套管均需在同一直线上,如果在安装时套管发生位移或旋转,将使以后的支管安装时丝扣无法对接,加大了工程难度,且难以修复。因此在一般情况下对于较粗的梁主筋,可承受压力的在梁两侧采用U型钢筋吊固。对细小的梁主钢筋,受压会变形的梁两侧采用X型支架钢筋架立。

止回阀存在的问题及处理措施

在消火栓进行试水时通常会发生消防泵运转正常,而顶层试验水枪压力不够。一种情况是止回阀安装错误,这主要是由于施工人员的粗心或者设计图纸在表示止回阀时流向画错,两者均能导致止回阀安装错误。另一种情况要检查止回阀是否完好,通常采用的办法是关闭水池消防出水闸阀,通过看水压是否上升或检视水池消防出水管处有无反水现象来断定止回阀的好坏,当止回阀坏时,应立即进行更换或维修。

5 装置管理策略

***1***装置安装前应对到场的装置启动全面的检查,并组织专员对装置进行例行保养。做好装置使用与维护保养工作,装置排程管理不仅要考虑水文、天气的影响及总工期要求,同时要考虑主导施工机械及配套机械的生产能力。另外,施工尽量避免冬季施工,冬季施工不仅使工程费用增加,也加大给排水装置的磨损。通过合理的装置组织,利用各分项工程之间进度的差异,进行分项工程之间同类装置的调遣,以便做好装置的维修保养。

***2***做好装置的使用及维护保养,给排水装置使用要严格遵守安全操作规程,装置在使用中发生异常,应停机检查,并向装置维修人员及时汇报。在工程施工中,加班加点的现象时有发生,对于施工中的重要装置,应定期组织人员进行检查保养,使装置始终处于良好的运作状态。

***3***做好装置的维修与技术革命。如果同类项目较多,在条件允许的情况下,可以多储存些总成件,既节省了原料,提高了功效又保证了工程质量。

***4*** 专案施工结束后对装置应进行全面的恢复修理。每一工序结束之后,应对所使用的机械进行全面检查,对于存在问题的给排水装置应及时组织修理,对于技术状况确实很差,现场修理难度大的装置,应交由专门的修理厂或维修部门修理,使专案竣工后设备处于完好状态。

参考文献

[1] 邓近贵.给排水施工专案质量问题的预防和控制分析[J].河南科技,2010,***4***.

[2] 赵宝山.建筑给排水设计施工中一些问题的探讨[J].给排水动态,2008,***2***.

[3] 余流.室内给排水安装工程中质量通病及其整治方法[J].中国建设资讯,2005.

>>>下页带来更多的

建筑给水排水期刊

《工业水处理》和《给水排水》是两款很权威的 可以在

《工业水处理》和《给水排水》是水处理杂志中两款很具有权威性的期刊杂志。《工业水处理》(月刊)创刊于1981年,是经国家科委和国家新闻出版署批准,由中国化工学会工业水处理学会、国家工业水处理工程技术研究中心和天津化工研究设计院共同主办的专业性科技刊物。是全国中文核心期刊、中国科技论文统计源期刊(中国科技核心期刊)、中国期刊方阵双效期刊。主要报道国内外有关循环冷却水、锅炉水、工艺用水及工业废水等的水处理技术动态、研究报告、专题述评、经验总结、科学管理及行业快讯等。读者对象主要是从事水处理工作的科研、设计、教学、生产、管理等单位的专业技术人员。《给水排水》月刊由中华人民共和国建设部主管,中国建筑设计研究院和中国土木工程学会给水排水学会主办。具有权威性、学术性、实用性、新颖性和信息性等特征,是同行业唯—一本综合性技术类期刊。拥有近百人的编委会和通讯员队伍,编委会委员由海内外给排水领域的专家组成。《给水排水》报道内容以实用技术为主,兼顾学术性和信息性,以城市、工业、建筑给水排水三者并重安排版面。现除设有城市给排水、工业给排水、建筑给排水。施工材料与设备等固定栏目外,还设有科技情报综述、策略研讨、标准规范简介。研究生论文摘要、信息市场等机动栏目。《给水排水》读者对象为从事设计、科研、教学、生产、施工安装、运行管理、房地产开发等单位及相关人员。

1、《工业水处理》

《工业水处理》(月刊)创刊于1981年,由中海油天津化工研究设计院主办、国家工业水处理工程技术研究中心协办,为全国中文核心期刊、中国科技论文统计源期刊(中国科技核心期刊)、中国期刊方阵双效期刊。每月20日出版。

2、《给水排水》

《给水排水》创刊于1964年,是中国建筑科学类中文核心期刊,中国科技论文统计源期刊。由中华人民共和国住房与城乡建设部主管,中国建筑设计研究院、中国土木工程学会、亚太建设科技信息研究院(建设部科技信息研究所)主办。

扩展资料

《工业水处理》主要报道工业废水、工艺用水、循环冷却水、锅炉水、市政污水、海水淡化等的水处理技术动态、研究报告、专题述评、经验总结、科学管理及行业快讯等。读者对象主要是从事水处理工作的科研、设计、教学、生产、管理等单位的专业技术人员。

订户遍及石油、石化、煤化、冶金、钢铁、电力、电子、纺织、印染、造纸、制药、机械、食品、饮料酿酒、交通、造船、矿业、环保、海水淡化等系统,自来水公司、污水处理厂、水处理设备工程公司,以及大专院校等。

参考资料来源:百度百科-给水排水杂志社

参考资料来源:工业水处理官网-杂志简介

在 国家新闻出版总署网站 上 根本查不到 《建筑给水排水》 这个期刊,应该是假期刊吧,是非法出版物。发了没有任何用处的。只能查到:《给水排水》、《中国给水排水》,但这两个 都是核心期刊。

建筑设备给水排水论文3000字

随着我国现代建筑技术的不断发展,人们对于建筑给排水工程方面也提出了越来越高的的要求。下文是我为大家整理的关于建筑给排水工程论文的范文,欢迎大家阅读参考!

浅谈高层建筑给排水工程设计

摘要:对高层建筑给水系统设计,排水系统设计、室内消防和热水系统设计进行了详细介绍,总结出目前高层建筑给排水存在的问题,并探讨了给排水节水措施,以确保水资源的合理利用。

关键词:建筑给排水;高层建筑;设计;节水措施

1、高层建筑给排水工程设计方法

高层建筑给水排水工程与一般多层建筑和低层建筑给水排水工程相比,基本的理论和计算方法是一致的,但因高层建筑层数多,高度大,结构复杂。近年来建筑给水工程设计方法得到改进。

例:给一个高层建筑为15层的楼房设计给排水:

住宅楼为框架结构,共15层,层高,室外给水管网位于建筑物的北侧,距离外墙为10m,接管点埋深,管径400mm,管材为球墨给水铸铁管,常年提供的水头;室内粪便污水需要经过化粪池处理方可排入市政管网,室外排水管网位于建筑物的南侧,埋深2m,管径600mm,管材为聚乙烯双壁波纹排水塑料管。

设计参数

生活用水定额:qd=150L/(人.d);最大小时生活用水量:Qh=;最高日用水量:Qd=;小时变化系数:kh=;每户人口:m=人;共90户;室内消防用水量:10L/s;消防水箱水量为火灾前10min的水量6m?;贮水池内的消防水量:按火灾延续2h的水量计;雨水重现期:2年。

设计内容

给水系统设计

管道采用钢塑复合管(内衬塑外镀锌)螺纹连接,进行干管安装、立管安装、支管安装,管道安装完毕需进行水压试验,压力设在,并对安装好的管道做好防腐和保温工作,冲洗管道对其进行管道通水试验。

根据《建筑给排水设计手册》上卫生器具的最大静水压力不得超过,因此高层建筑给水系统必须分区。设计任务书给定了市政给水管网提供常年的水压为。根据给水最小所需压力估算方法:第1层,第2层,2层以上增加1层,压力需增加。得的压力能直接供到第6层还多。所以1层~6层为一个区,上面7层~15层为一个区,总共就两个区。1层~6层用市政管网直接供水,其中底层和2层~6层单独设立管。

考虑到此设计对象是15层的高层建筑。市政管网提供的压力不能全部直接供水,所以必须对生活用水进行提升或加压。高层建筑设计一般都使用高位水箱供水,供水压力比较稳定,此设计也使用高位水箱;又因此设计面向高层民用住宅楼,通过查看平面图纸,根据建筑物的布置情况和楼层的承载力情况及水箱本身占用大量的建筑面积,即在楼层中间没有建筑面积可允许安置水箱,串联供水不可实现,因此高区的供水应在地面用泵抽升到高区水箱。

方案(一)与方案(二)相比管材使用量、工程投资相对较少,但它对减压阀的质量要求相对较高,一旦减压阀受损或使用性能降低,低区的静水压力会迅速增加,影响卫生器具的使用。方案(二)采用低区市政管网直接供水,消除了通过依赖减压阀降低静水压力来减少低区供水的现象。基于工程质量和供水水质及水压的可靠性,最终选择方案(二)

排水系统设计

室内排水系统为污水、废水合流系统,地上部分直接排出室外,地下部分分段设置集水坑把地下室污水、废水汇集于坑内,利用潜水泵由集水坑自动控制将其提升至室外。为了保护存水弯水封性能,保持排水系统内的空气压力与大气压取得平衡,使排水管内排水畅通,向排水管内通入新鲜的空气,保持管内的换气,防范因室外管道系统积聚起来的有害气体而伤害到养护人员、引发火灾和腐蚀管道等隐患,还应减少排水系统的噪声,在排水系统中设置通气管。

室内消防工程

室内消火栓给水系统有:分区、不分区两种方式。消火栓的静水压力超过时就需要分区供水,而本设计是15层的小高层,高度不超过50m,静水压力小于,可以不分区。同时本设计的建筑是15层小高层民用住宅楼,造成火灾的隐患少,人员疏散也快,扑救难度不大,高压消防给水无须设置常年的。设置专用的消防泵,从贮水池内抽取消防水,可用生活给水箱在火灾发生初期10min提前给水,并设置止回阀,既消除了消防水箱对楼层负荷,又可减少工程投资。此设计是15层小高层,层高,总楼高不超过45m,根据建筑给排水设计手册!规定消防栓的最大静水压力不超过,此设计无须分区消防供水,可利用消防泵直接供水满足条件。

室内热水工程

应根据建筑物的用途、热源的供给情况、热水用量和卫生器具的布置情况进行技术和经济比较来确定何种热水供应方式。热水供水方式有如下几类。按供应范围不同有:集中供热、局部供热、区域供热。

2、目前建筑给排水存在的问题

控制超压出流产生的水量浪费

生活给水系统按规定竖向分区后仍然存在着部分卫生器具配水点水压偏大的问题,而这是常常被忽视的。卫生器具的额定流量少于单位时间内的出水量,影响给水系统正常分配水的流量。如不采取减压节流措施,将造成水资源浪费、水压过高、漏水量增加等弊病,同时易产生水击、噪声和振动,致使管件损坏和破裂。这些水量的浪费不容忽视。

管道和阀门的损坏

我们可看到的路边给水管道在管子接缝处及法兰、阀门连接处向外冒水,而我们看不见的地下更不知有多少漏水处。管道受损及腐蚀,阀门不严等问题导致大量水流失。

热水系统浪费水量巨大

建筑热水供应已成为建筑给水的重要部分,由于设计不当,其浪费已非常严重,造成一定损失。所以给水系统供水应保证冷热水压力均衡,采用循环系统以确保每户开龙头就有热水,降低水量浪费。

3、我国建筑给排水节水措施

提高用水效率

1)严格执行生活用水量定额标准,饮用水、生活用水、景观用水、绿化用水按各个水质要求分别供给。

2)采用节水系统,如节水的卫生器具,利用限制卫生器具的流出水头、红外线感应龙头和便器等。

3)选择一个可再生能源,如风能、太阳能、水能、海洋能、地热能、生物能等非化石能源用于建筑的热水供应。对于不同的场合采用不同的热源形式。

雨水的利用

利用雨水收集系统再循环得到符合标准的水质进行绿化浇灌,处理后的雨水还可用于冲洗厕所,这不仅可减少用水量还可减轻污染。提高地基的保水能力,合理规划雨水流经途径,引入雨水沉淀池再利用。

污水排放和二次利用

建筑中水系统是典型的资源可持续利用装置,将建筑物产生的污水、废水加以收集并对其处理,在节省资源和保护环境的基础上对生活污水和废水的重复利用。

节水指标

节水指标有三类:

1)雨洪水利用率:常年降雨量除以使用或收集量;

2)水使用率:正常使用量除以使用量;

3)循环量:一次性用量乘以循环次数。

4、结语

在给排水设计时,我们应正确合理的选择系统和方案,以达到节水节能的目的,确保水资源的合理利用。

参考文献:

[1]孙志魁.我国绿色建筑给排水节能新技术的应用新探.中国新技术新产品,2012(1):45.

[2]杨天峰,张旺.低碳经济下建筑给排水的节能问题研究.科技创业月刊,2010,23(9):161-162.

[3]赵培林.浅议绿色建筑住宅的节水设计.机电产品开发与创新,2009,22(3):40-41.

[4]李倩.绿色建筑给排水设计的节水途径探析.企业导报,2012(1):273.

浅析建筑工程给排水施工技术

摘要:本文作者结合实际工作经验,对建筑工程的给排水施工技术进行了分析,提出了自己的见解。

关键词:建筑工程;给排水;施工技术

随着我国现代建筑技术的不断发展,人们对于建筑给排水工程方面也提出了越来越高的的要求。在设计和施工时要不断积累经验,深入分析各种常见问题,促进给排水施工技术的发展。

1 建筑给水方面的管道施工

给水管道材料的种类和选用

现在在新型建筑中用的较多的给水管材主要包括:聚丙烯类、聚乙烯类、聚丁烯类、工程塑料类,以及还有一些复合管类,例如:钢塑管、铝塑管、铜塑复合管等。虽然可供选择的材料有许多种,但在每一个具体施工工程中也必须根据实际情况进行选择。而且在管材的选用上还受到许多因素的影响,必须对国家政策、施工标准、地区特点、工程性质以及施工标准等因素进行综合考虑,选择最优管材。其中还要特别注意的是,管道的使用位置以及其使用方法是在管材选用时需要着重考虑的,还有就是管件与连接也是选取管材时容易忽视的一个关键的问题。

给水管道的施工

在对给水管做热熔连接时,必须要掌握好加热的时间和连接将要插入的深度。如果加热时间过长就使水管融化,如果加热时间过短也不能更好连接;如果插的过深,就会造成管道断面减少;如果插的过浅也会使降低接口处强度。所以,加热时的温度、加热时间和接缝压力是影响热熔连接质量的三个关键因素。

2 建筑排水管道常见问题的原因分析

排水管道方面经常出现的问题是漏水、堵塞问题。出现这些问题的原因也比较多,第一,就是施工中出现的问题,大多是施工单位没有选择合格的管材,为了一时经济利益以次充好,或者是在安装前没有进行漏水实验,也或是一些不合格的材料运用到工程中导致漏水现象的发生;比如说管道穿墙(楼板)设置套管的缺陷与不足较为普遍。有的虽然加了套管,穿越楼板与楼板面齐平或嵌入楼板有的穿越墙面,比饰面多出20-50mm,有的没有设套管或预埋套管偏位,于脆用水泥圈(楼面)塑料圈(墙面)护(粘)住,掩人耳目,有的套管比管道只大一个规格,有的大三至五个规格,套管与管道间隙有的用泡沫、油麻堵塞等等套管的设置应按(GB50242-2002)规范第规定.“安装在楼板内的套管,其顶部应高出装饰地面20mm,安装在卫生间及厨房内的套管,其顶部应高出装饰地面50mm,底部应与楼板底面相平,安装在墙壁内的套管其两端与饰面相平。穿过楼板的套管与管道之间缝隙应用阻燃密实材料和防水油膏填实。端面光滑。穿墙套管与管道之间缝隙宜用阻燃密实材料填实,且端面应光滑。管道的接口不得设在套管内”。第二,就是设计方面出现了问题,导致管道安装好以后容易堵塞;第三,就是住户使用时出现了问题。

3 建筑给排水施工的特点

管道安装具有的特点

在这几年里,给水管道的材料大多使用的是PP-R管和UPVC管。因为这两种管道具有轻便、耐高压、抗腐蚀、质量安全、使用卫生、通水阻力小、使用寿命较长的特性,所以安装中最明显的特点就是便于安装。对于PP-R管的安装来说,连接前要清除管道上附着的灰尘后,在按照严格的施工流程来进行安装,但是其中需要注意的是在在对管道进行热熔是一定不能旋转,以免加热过度,而且在管道连通后还要采取一定措施对其进行冷却。对于UPVC管的安装来说,安装时一定要使用排水胶粘结。在涂完胶以后还要注意的就是胶干时间,具体的时间应依据当地气候和温度的变化来进行调节,还要注意不能沾水。如果是在环境温差较大的地方安装,必须使用管道伸缩节。

给排水管道的试压

当所有管道安装完成之后,还要对所有部位进行全面的检测,主要包括检测已安装的管道和阀门等设备是否符合设计和技术要求规定,如果有问题应立即拆除予以更换或是维修。检测的具体方法是用临时的短管来替代安装的管道,把所有的开口处封闭,从管道最低处开始灌水,在最高处进行放气。如果出现异样,要及时停止检测,并立即排水。在试压完成后,还对所有管道要进行吹洗。

4 提高建筑的给排水施工技术的具体措施

随着建筑技术的发展,生产工艺的不断改进和提高,对给排水工程的设计、施工、维修和运行管理的要求也就越来越高。要想使管网达到优质、高效、低能耗运行的目的,除要有合理的设计方案外,给排水系统安装质量的优劣将会对日后的使用产生极大的影响。

管道施工的措施

对于管道的施工来说主要是注意加热时间、加热温度、接缝压力这三个方面的问题,施工中运用最多的是钢塑复合管,在对其施工中应采用螺纹连接的方法,插入管道的长度应严格按照标准旋转深度进行控制;在对管端和管螺纹进行加工后,还要进行密封处理,这时需要使用聚四氟乙烯生料带来进行缠绕螺纹;施工中需要选用厌氧密封胶密封过的管道接头,必须在养护24h之后再进行试压。施工中要用专门的施工机具,不能随便更该。

W型铸铁管的施工方法

有关W型铸铁管的具体施工措施,第一步就是下料,在切割管材时要选用专门的切割工具,主要是保证管口的平直。第二步是连接,进行连接时先要松开卡箍,再取出内衬中的橡胶圈,把箍套和橡胶圈放在入管口的一侧,使管口对齐后,随后把橡胶圈放在接口上,最后锁紧了箍套紧固了螺丝就算完成了管道连接。第三步低支架的设置,对于一般的管材安装来说,如果每隔3m设置一个支架其实是可以的,但是对于W型无承口机制排水铸铁管接口来说就不行了,因为其属于柔性接口,当支架放在管道中间时,理论上可以将管道保持平衡,可是在实际工作中,找到重心点是很难的,所以经常无法保证管道接口的平滑,如果采用每隔设置一个支架的方法来进行布置,这样就可以很好地解决管道外观和管道坡度的问题。

建筑给排水施工的监管

给排水管道的设计与施工是一项很复杂的措施,其中关于管道的铺设和管道的安装都容易出现问题,所以有关管道施工的监督也是一项非常重要的方面。因为管道施工工期较长设计建筑工程的的许多阶段,所以监管也可以分为多个阶段来进行。

首先,在工程施工前期阶段的监管,在施工前就应该仔细阅读施工图纸,充分了解设计者的设计意图和目的,这样才能保证施工过程中不偏离设计图纸的要求,也不能在施工中随意变更设计方案。

其次,是在基础主体结构施工阶段的监管,在基础主体施工中,要注意排水系统的排水管和给水管的引入管在穿越建筑物或地下构筑物外墙处时,是否按设计要求预留好了足够的孔洞以及设置好的套管。

再次,就是装修阶段的监管,在装修施工阶段主要是对给排水管道系统安装阶段,主要是注意装修工程不能破坏原有的管道路线的设置或是预留管道的破坏,必须在明确所有管道布置之后再结合装修方案进行施工。

5 结束语

随着我国建筑技术的不断发展,对给排水工程的设计、施工和运行管理等方面的要求也越来越高。优质的安装施工质量和科学的管理是保障管网系统高效安全运行的必要条件。为了满足给排水建筑施工技术要求,提高施工质量,需要施工人员不断学习,提高自身的技术素质,只有这样,才能保证安装工程的质量,立足于建筑安装工程的基本建设。

参考文献:

[1] 王胜飞;民用建筑给排水工程施工质量常见问题及预防措施[J].中小企业管理与科技(下旬刊),2010,(08).

[2] 金生;建筑工程给排水施工常见问题解决措施探讨[J].现代商贸工业,2011,(09).

[3] 刘康;建筑工程给排水施工常见问题及解决措施研究[J].科技致富向导,2011,(01).

[4] 何新辉,魏晓斌.高层建筑给排水设计分析研究[J].中国房地产业,2011,(04).

[5] 李霞,高层建筑给水排水工程课程教学实践与探讨[J].山西建筑,2011,(01).

写作思路:根据题目要求,以建筑设备作为主题,详细记录哪些必要的设备,最后进行总结。正文:

1、建筑设备工程施工技术

为了让建筑设备工程更好运行和发挥作用,首先就应该把握施工技术要点,做好设备安装。但在日常工作中,一些施工人员的技术水平较低,责任心不强,导致设备安装存在问题与不足,制约建筑设备工程更好运行和发展作用。今后应该转变这种情况,把握施工技术要点,促进建筑设备工程质量提高,也为建筑工程施工效率提高创造便利。

施工准备工作。为促进设备安装顺利完成,首先应该做好准备工作,建筑设备采购之前,采购员应该严格按照图纸要求进行,对永久性使用的设备,严格按照规定制定采购计划,报相关部门审批,然后按照要求采购。

收货时按照要求对设备进行验收,检查设备是否满足施工规范要求,材料是否合格,零配件是否满足要求,采购的设备是否存在问题,具备合格证和质量保证书。如果是成套大型设备,更应该做好设备验收工作,在有监理工程师和业主在场的情况下,经检查无误之后进行验收,确保设备质量,为接下来进行安装和设备运行创造良好条件。

设备安装技术。安装时要把握每个技术要点,保证安装施工质量提高。重视对设备的位置度、严密性和强度进行严格控制,最好进行设备耐压试验,有效保障设备质量。遵循设计规范要求和技术标准安装设备,把握每个技术要点,避免设备安装时出现故障,促进设备安装质量提高。

重视对地脚螺栓安装质量控制,由于其安装工艺复杂,难度较大,质量控制比较困难,并且容易出现倾斜现象,可能导致较大的误差,如果质量控制不到位,容易使得设备出现整体故障,影响其正常运行和工作。

另外,设备摩擦容易使轴承产生大量热量,导致该问题出现的原因是润滑油太少,润滑油洁净度不够,轴承间的缝隙调整不当等。为预防这些问题出现,首先就要合理调整轴承间的缝隙,做好润滑工作,确保润滑油质量,避免设备出现过热现象,确保建筑设备安装工程质量。

试运转技术。建筑设备安装完成之后,要进行试运转,在空载、满载、正常状态下运转,做好相关数据记录工作,掌握设备运行情况。试运转时应该做好设备各项性能和数据指标的记录工作,对设备性能进行全面分析,对存在的缺陷及时改进和完善。这样一来,就能实现对设备性能的有效保障,为建筑施工顺利进行奠定基础。

提高施工人员技术。注重对技术水平高,基础知识扎实的技术人员引进工作,重视提高建筑设备工程施工技术人员专业素质,使他们更好适应各项工作需要。加强对他们的管理和培训,提高施工人员素质,能熟练的操作建筑设备,促进工程建设效益提高。

2、建筑设备工程施工管理

除了把握施工技术要点,确保建筑设备工程更好运行和发挥作用之外,还应该加强施工管理,提高质量和安全管理水平,推动建筑设备工程施工效率提高。

材料管理。采购建筑设备各项材料之前,对供应商基本情况进行调查,做好对各项设备的采购工作,确保材料质量合格,为更好开展工作奠定基础。同时还要对材料进行检验,有效保障材料质量合格,为建筑设备安装和施工顺利进行奠定基础,促进工程建设质量提高。

质量管理。设备工程施工之前,要提高工程质量控制水平,做好图纸设计工作,对各项设备安装进行科学合理安排,制定科学合理的施工方案,做好技术交底工作,明确施工任务和要求,促进建筑设备工程施工顺利进行。

重视施工现场巡视工作,做好各项设备处理工作,及时发现存在的问题与不足,采取有效的措施处理和应对,保障工程质量提高。

现场管理。施工单位要配备工作人员,做好对施工现场的巡视,完善现场检查,加强对施工机械和设备、施工人员的检查,确保设备正常作用发挥。重视设备日常维护工作,及时添加润滑油,促进设备使用性能最佳发挥。

对设备存在的缺陷也要及时处理和应对,避免施工现场因设备质量不合格而出现质量事故,提高建筑设备施工效率。

安全管理。完善施工安全管理规章制度,明确施工人员管理责任,推动安全管理的规范化和制度化进程。完善现场安全巡视工作,及时排除存在的安全隐患,将安全事故消灭在萌芽状态,推动建筑施工顺利进行。建立安全事故应急处理机制,及时处理和应对突发事件,尽量降低安全事故带来的损失。

试验检测。及时对各项设备进行试验检测,全面掌握设备综合性能,对存在故障的设备立即采取措施处理,从而确保设备质量和性能提高,使其更好运行和发挥作用,促进建筑设备工程运行效率提高,更好发挥相应的作用。

3、结束语

要想促进建筑设备工程更好运行和发挥作用,首先就得把握施工技术要点,加强施工管理,确保设备性能良好,促进运行效率提高。另外还要重视设备工程的日常维修和保养,使其处于良好的性能和工作状态,推动建筑工程施工效率提高,保障工程建设质量和效益。